首页> 外文期刊>The American Journal of Clinical Nutrition: Official Journal of the American Society for Clinical Nutrition >Comparative measurements of total body water in healthy volunteers by online breath deuterium measurement and other near-subject methods.
【24h】

Comparative measurements of total body water in healthy volunteers by online breath deuterium measurement and other near-subject methods.

机译:通过在线呼吸氘测量和其他近距离受试者方法对健康志愿者体内总水分的比较测量。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: We developed a new near-subject approach, using flowing afterglow-mass spectrometry (FA-MS) and deuterium dilution, which enables the immediate measurement of total body water (TBW) from single exhalations. OBJECTIVES: The objectives were to show the efficacy of the new FA-MS method in measuring TBW in healthy subjects and to compare these measurements with values derived from multifrequency bioelectrical impedance analysis, skinfold-thickness (SFT) measurements, and both recent and historical published regression equations. DESIGN: After baseline measurement of breath deuterium abundance, 24 healthy subjects ingested 0.3 g D(2)O/kg body wt. A second breath sample was taken after 3 h to measure the increase in deuterium, from which TBW was calculated. Bioelectrical impedance analysis was carried out with a multifrequency analyzer, and SFT was measured by a single trained observer. Methods were compared with the use of Pearson's correlation coefficient and Bland-Altman analyses. RESULTS: TBWmeasures obtained by all methods were highly correlated (r = 0.95-0.98, P < 0.001), especially those between FA-MS, SFT measurement, and recent regression equations. The mean values obtained were within 2% of those published for age-matched control subjects and varied by 1-6% when all methods were compared. Systematic bias was greatest when FA-MS was compared with bioelectrical impedance analysis, which tended to underestimate TBW in smaller, female subjects. No bias related to subject size was observed in a comparison of FA-MS with SFT measurement or with more recent regression equations. CONCLUSIONS: FA-MS is a simple and effective new approach to TBW measurement in healthy subjects. The difficulty of using population-derived equations to estimate TBW in individual subjects is emphasized.
机译:背景:我们使用流动的余辉质谱(FA-MS)和氘稀释法开发了一种新的近主体方法,该方法可立即测量一次呼气中的全身水(TBW)。目的:目的是展示新的FA-MS方法在健康受试者中测量TBW的功效,并将这些测量结果与多频生物电阻抗分析,皮褶厚度(SFT)测量以及最近和历史发表的值进行比较回归方程。设计:基线测量呼吸氘的丰度后,24名健康受试者摄入了0.3 g D(2)O / kg体重。 3小时后再进行一次呼吸采样以测量氘的增加,由此计算出TBW。用多频分析仪进行生物电阻抗分析,并由一名训练有素的观察员测量SFT。将方法与使用Pearson相关系数和Bland-Altman分析进行了比较。结果:所有方法获得的TBW测量值高度相关(r = 0.95-0.98,P <0.001),尤其是FA-MS,SFT测量和最新回归方程之间的测量值。所获得的平均值在与年龄匹配的对照受试者所公布的平均值相差2%之内,当比较所有方法时,其平均值相差1-6%。将FA-MS与生物电阻抗分析进行比较时,系统偏倚最大,这往往低估了较小的女性受试者的TBW。在FA-MS与SFT测量或最新回归方程的比较中,未观察到与受试者体型相关的偏见。结论:FA-MS是一种简单有效的健康受试者TBW测量新方法。强调了使用人群衍生方程估算个体受试者的TBW的难度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号