In a series of 90 Medial Pivot arthroplasties rotational alignment of the femur was achieved by provisionally reconstructing the lateral side of the joint and tensioning the medial side with feeler gauges. Axial CT scans were employed to measure the rotational alignment relative to surgical epicondylar axis. In valgus knees the cutting block was externally rotated to adjust for posterolateral bone loss. The mean rotational alignment of the femur was 0.6 degrees of external rotation (S.D. 1.3, range 3 degrees of ER to 4 degrees of IR). The mean laxity of the medial ligament was 1 mm in flexion (SD 1, range 0-5 mm) and 0.5 mm in flexion (S.D. 0.5, range 0-2 mm) In those knees in which the medial ligament had been released the CT alignment was perfect, but when internally rotated against the hip 3-4 mm of gapping was noted. In valgus knees the mean rotation of the femoral component was 0.8 degrees of internal rotation (S.D. 1.5, range 1 degrees of IR to 4 degrees of ER). In spite of externally rotating the cutting block there was still a tendency to internally rotate the femur in some knees. This simple technique achieves the two goals of ligament stability and correct rotational alignment in a high proportion of cases. It may be applicable to any instrument system which employs posterior referencing.
机译:在一系列的90个内侧枢轴关节置换术中,通过临时重建关节外侧并用塞尺规拉紧内侧来实现股骨的旋转对齐。使用轴向CT扫描来测量相对于手术epi上轴的旋转对准。在外翻膝盖中,切块向外旋转以适应后外侧骨丢失。股骨的平均旋转方向为外旋0.6度(S.D. 1.3,ER的3度到IR的4度)。内侧韧带的平均松弛度为屈曲1 mm(SD 1,范围0-5 mm)和屈曲0.5 mm(SD 0.5,范围0-2 mm)在已释放内侧韧带的那些膝盖中,CT对齐是完美的,但是当内部旋转抵靠臀部时,会留出3-4毫米的间隙。在外翻膝盖中,股骨组件的平均旋转为内部旋转的0.8度(标准偏差1.5,IR的范围为1到ER的范围为4)。尽管从外部旋转切割块,但仍有一些膝盖内部向内旋转股骨的趋势。这种简单的技术可以在很大比例的情况下实现韧带稳定性和正确的旋转对准这两个目标。它可能适用于采用后参考的任何仪器系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号