首页> 外文期刊>The Journal of trauma >Clinical study and comparison of magnetic resonance angiography (MRA) and angiography diagnosis of blunt vertebral artery injury.
【24h】

Clinical study and comparison of magnetic resonance angiography (MRA) and angiography diagnosis of blunt vertebral artery injury.

机译:磁共振血管造影(MRA)和血管造影诊断钝性椎动脉损伤的临床研究与比较。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Two-dimensional time-of-flight (2D TOF) magnetic resonance angiography (MRA) is the major method for detecting vertebral artery injury (VAI). But there is still controversy over MRA's accuracy in detecting VAI of varying degrees, a technique for which there are no animal studies found in the literature. The purpose of this study was to evaluate the value of MRA for detecting vertebral artery injury in cervical spinal trauma patients and to conduct a comparative study of MRA and angiography of blunt vertebral artery injury in an animal experiment. METHODS: In clinical study, 319 patients with close cervical spinal trauma underwent 2D TOF MRA prospective examination. The strike-induced flexion injury model of the cervical spine was constructed based on animal experiment with 14 adult dogs. X-ray studies were performed immediately after injury. 2D TOF MRA and angiography were formed within 24 to 36 hours. RESULTS: Vertebral artery injury was detected by 2D TOF MRA in 52 of the 319 patients. Ofthe 52 patients, there were 51 unilateral vertebral artery injuries, including 22 injuries on the left vertebral artery and 29 on the right vertebral artery. One patient sustained bilateral vertebral artery injury. Seven dogs had unilateral VAI (5 on the left, 2 on the right), and two dogs had narrower-than-normal left vertebral arteries on MRA examination. Angiography showed occlusion exactly in seven dogs with unilateral vertebral artery injury detected by MRA and no abnormal findings were detected in five dogs without vertebral artery injury on MRA. In two dogs with incomplete left vertebral artery flow-related enhancement on MRA, angiography showed occlusion in one dog and no vertebral injury with normal image in the other. CONCLUSIONS: 2D TOF MRA is an effective detection method of blunt vertebral artery injury but it might not be able to differentiate spasm, a small disruption of intima, from others under certain conditions.
机译:背景:二维飞行时间(2D TOF)磁共振血管造影(MRA)是检测椎动脉损伤(VAI)的主要方法。但是,关于MRA检测不同程度的VAI的准确性仍存在争议,该技术在文献中未发现任何动物研究。这项研究的目的是评估MRA在颈椎创伤患者中检测椎动脉损伤的价值,并在动物实验中进行MRA和钝性椎动脉损伤血管造影的比较研究。方法:在临床研究中,对319例颈椎闭合性闭合性创伤患者进行了2D TOF MRA前瞻性检查。基于动物实验,对14只成年犬进行了颈椎罢工诱发的屈曲损伤模型的研究。受伤后立即进行X光检查。在24至36小时内形成2D TOF MRA和血管造影。结果:319例患者中有52例通过二维TOF MRA检测到椎动脉损伤。 52例患者中,单侧椎动脉损伤51例,其中左椎动脉22例,右椎动脉29例。 1例患者双侧椎动脉损伤。在MRA检查中,七只狗有单侧VAI(左5头,右2头),两只狗的椎骨动脉比正常狭窄。血管造影显示,通过MRA检测到7例单侧椎动脉损伤的狗完全闭塞,在5例没有MRA椎动脉损伤的狗中未发现异常发现。在两只MRA不完全相关的左椎动脉血流增强的犬中,血管造影显示,一只犬发生阻塞,另一只犬没有椎体损伤,影像正常。结论:二维TOF MRA是一种检测钝性椎动脉损伤的有效方法,但在某些情况下可能无法将痉挛,内膜小的破坏与其他疾病区分开。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号