Severe coagulopathy is a common entity during biventricu-lar assistance and is particularly difficult to deal with when using bivalirudin as an anticoagulant. Resultant severe coagulopathy can causes relentless bleeding, even from needle holes and graft interstices. We report the use of Esmark (Advanced Medical Designs, Marietta, Ga) as an clastoplas-tic bandage to tamponade bleeding from a ventricular assist device outflow graft. A 34-year-old woman with a history of right lower extremity osteosarcoma had adriamycin-induced cardiomyop-athy. After long-term clinical stability, pregnancy resulted in decompensation, premature loss of pregnancy, and placement of a Tandemheart (Cardiac Assist, Inc, Pittsburgh, Pa) percutaneous left ventricular assist device (LVAD). After improvement and weaning from the device, hemody-namic decompensation again occurred, prompting redo percutaneous LVAD placement and surgical referral for long-term bridge to transplantation therapy. Biventricular assistance was deemed necessary. Secondary to heparin-in-duced thrombocytopenia, bivalirudin was used for cardio-pulmonary bypass, with activated clotting times reaching as high as 700 seconds. A Heartmate II Axial flow device (Thoratec Corp, Pleasanton, Calif) was placed in the left ventricle-to-aorta configuration. The Tandemheart pump previously used as the percutaneous LVAD was recycled on the operative field and used as a right ventricular assist device with percutaneous right atrial inflow and outflow to the pulmonary artery.
机译:严重凝血病是双心室协助期间的常见现象,当使用比伐卢定作为抗凝剂时尤其难以治疗。严重的凝血病可导致不停的出血,即使是从针孔和移植物的空隙中也是如此。我们报道了使用Esmark(先进医疗设计公司,佐治亚州玛丽埃塔)作为clastoplastic绷带,用于从心室辅助装置流出移植物中压塞出血。一名有右下肢骨肉瘤病史的34岁妇女患有阿霉素诱导的心肌运动。经过长期的临床稳定性,妊娠导致代偿失调,妊娠过早丧失,并放置了坦坦心脏公司(Cardiac Assist,Inc,Pittsburgh,Pa)的经皮左心室辅助装置(LVAD)。改进并从设备中撤机后,再次发生血流动力学失代偿,促使重做经皮LVAD放置并进行手术转诊以长期移植治疗。认为需要双心室协助。继肝素诱导的血小板减少症之后,比伐卢定用于心肺分流术,激活的凝血时间高达700秒。将Heartmate II轴流设备(Thoratec Corp,加利福尼亚州普莱森顿)放置在左心室到主动脉的位置。先前用作经皮LVAD的Tandemheart泵在手术现场被回收,并用作右心室辅助设备,经皮右心房流入和流出肺动脉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号