首页> 外文期刊>The journal of sexual medicine >Erectile function significant enough for penetration during sexual intercourse after removal of inflatable penile prosthesis
【24h】

Erectile function significant enough for penetration during sexual intercourse after removal of inflatable penile prosthesis

机译:勃起功能足以去除可膨胀的阴茎假体后进行性交

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction. Fifty-two-year-old male with history of multiple insults to his erectile tissue, including insertion and removal of penile implant, presents with significant partial erectile function, substantial enough for anal penetration during sexual intercourse. Aim. Erectile function rigid enough for anal penetration, let alone any erectile function after removal of an inflatable penile prosthesis (IPP), is rare. This article, to our knowledge, is the first case of a patient who has undergone multiple insults to his erectile tissue, including an episode of ischemic priapism followed by implantation and removal of an IPP, who presents with erectile function sufficient enough for coitus. Main Outcome Measures. Outcome measured via standardized patient questionnaires and penile Doppler following injection of Trimix. Method. An objective measure of the patient's erectile function was performed via penile Doppler. Results. Penile Doppler after 10-mcg injection of Trimix revealed numerous perforating vessels from the corpora spongiosum providing blood flow to the corpora cavernosa. The patient obtained approximately 60-70% rigid erection. Conclusions. To our knowledge, and after thorough review of the literature, we could not find any reports of erectile function significant enough to take part in sexual intercourse and penetration after removal of a three-piece IPP. The implant usually disrupts the normal anatomy which allows for cavernosal arterial vasodilation and increased blood flow into the corpora. Following dilation of the corpora the cylinders are inserted and inflated, and the smooth muscle that makes up the corpora cavernosum is compressed against the wall of the tunica albuginea. Theoretically, the remaining smooth muscle tissue may retain some of its physiologic function, adding some additional girth to the penis with an already activated IPP during sexual intercourse.
机译:介绍。五十二岁的男性有多次勃起组织病史,包括阴茎植入物的插入和拔出,表现出明显的部分勃起功能,足以在性交期间穿透肛门。目标。足够坚硬的勃起功能足以穿透肛门,更不用说在移除可膨胀的阴茎假体(IPP)之后的任何勃起功能。据我们所知,这是第一例患者多次勃起组织受到侮辱的情况,包括缺血性阴茎异常发作,然后植入和取出IPP,其勃起功能足以应付性交。主要观察指标。注射Trimix后,通过标准化的患者问卷和阴茎多普勒测量结果。方法。通过阴茎多普勒对患者的勃起功能进行客观测量。结果。注射Trimix 10 mcg后,阴茎多普勒显示海绵体中有许多穿孔血管,从而为海绵体提供了血流。患者获得了大约60-70%的刚性勃起。结论。据我们所知,在对文献进行全面回顾之后,我们发现没有任何重要的勃起功能报告足以移除三片式IPP后参与性交和性交。植入物通常会破坏正常的解剖结构,从而导致海绵体动脉血管舒张并增加流入体的血流量。扩张主体后,将圆柱体插入并充气,然后将组成海绵体的平滑肌压在白膜上。从理论上讲,剩余的平滑肌组织可以保留其某些生理功能,在性交过程中,已经激活了IPP的阴茎会增加一些周长。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号