...
首页> 外文期刊>The Journal of Urology >Safety and effectiveness of a new saline filled testicular prosthesis.
【24h】

Safety and effectiveness of a new saline filled testicular prosthesis.

机译:一种新型生理盐水填充睾丸假体的安全性和有效性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Testicular prostheses have been used for 50 years to replace missing or removed testes. In 1995 the manufacture of the silicone gel filled testis prosthesis in the United States was discontinued because of concern about the safety profiles of other implants. We assessed the safety and effectiveness of a new, saline filled implant for testicular replacement. MATERIALS AND METHODS: This open label, multicenter, prospective, case controlled clinical trial was done at 18 American tertiary referral centers. Adult and pediatric male patients missing 1 or 2 testes and without evidence of active malignancy or rheumatological disease were enrolled. All patients underwent formal rheumatological and urological evaluation prior to and after prosthesis placement. Main outcome measures were prosthesis safety assessed by adverse events and effectiveness assessed by changes in testis dimension. Secondary outcome measures were quality of life assessments with 3 validated instruments. All patients were followeda minimum of 1 year in this 5-year study. RESULTS: Postoperative adverse events observed in 19% of 149 patients included device related discomfort or pain in 3%, scrotal edema in 1.3%, infection in 1.3%, extrusion in 2.6%, deflation in 0.7% and pulmonary emboli in 0.7%. No patient reported rheumatological symptoms at 1 year. Testis dimensions were significantly increased in patients missing a testis at baseline (p <0.001). Subjective assessment of testicular appearance was significantly improved (p <0.001) and scores were stable or significantly improved in 2 of 3 quality of life instruments. CONCLUSIONS: At short-term followup a new, saline filled testis prosthesis appears safe and well tolerated. Importantly validated self-esteem measures also suggest improvement in quality of life after prosthesis placement.
机译:目的:睾丸假体已经使用了50年,以替代遗失或切除的睾丸。由于担心其他植入物的安全性,1995年停止在美国生产填充硅胶的睾丸假体。我们评估了一种新的盐水填充植入物用于睾丸置换的安全性和有效性。材料与方法:该开放标签,多中心,前瞻性,病例对照的临床试验在18个美国三级转诊中心进行。入选了缺少1或2个睾丸且无活动性恶性肿瘤或风湿病证据的成年和儿科男性患者。所有患者在放置假体之前和之后均接受正式的风湿病和泌尿科评估。主要结果指标是通过不良事件评估假体安全性,并通过睾丸尺寸变化评估有效性。次要结果指标是使用3种经过验证的工具进行的生活质量评估。在这项为期5年的研究中,所有患者均接受了至少1年的随访。结果:149例患者中有19%发生了术后不良事件,其中与器械相关的不适或疼痛占3%,阴囊水肿占1.3%,感染占1.3%,挤压占2.6%,放气占0.7%,肺栓塞占0.7%。一年没有患者报告风湿病症状。基线时缺少睾丸的患者睾丸尺寸显着增加(p <0.001)。在3种生活质量工具中,有2种对主观睾丸外观的主观评估显着改善(p <0.001),并且评分稳定或显着改善。结论:在短期随访中,新的,充满生理盐水的睾丸假体看起来安全且耐受良好。重要的有效自尊测验也表明假体放置后生活质量的改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号