Kinetic analysis of monomer conversion in auto- and dual-polymerizing modes of commercial resin luting cements.

机译:商业树脂胶结水泥在自动和双聚合模式下单体转化的动力学分析。

获取原文
获取原文并翻译 | 示例

摘要

STATEMENT OF PROBLEM: Lack of knowledge regarding the kinetics of the setting reaction of dual- and autopolymerizing resin luting agents (RLA) leads the clinician to underestimate the care required during occlusal adjustments of indirect restorations. PURPOSE: The purpose of this study was to evaluate the degree of conversion (DC), maximum rate of polymerization (R(p)(max)), and potential of cure (ratio of conversions in autopolymerized relative to dual-polymerized modes; PC(A/D)) of 5 dual-polymerizable RLAs at 5 and 10 minutes, after mixing RLA components using infrared (IR) spectroscopy. MATERIAL AND METHODS: The RLAs evaluated included Calibra, Duo-Link, Lute-It, Nexus 2, and RelyX ARC. The RLAs were manipulated and applied to the horizontal diamond element in the optical bench of an IR spectrometer. The materials were either light activated for 40 seconds (dual-polymerizing mode) or were allowed to autopolymerize (autopolymerizing mode). The DC, R(p)(max), and PC(A/D) were calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios before and after polymerization. Data (n=5) were analyzed by 2-way repeated measures ANOVA and Tukey's post hoc test (alpha=.05). RESULTS: All autopolymerizing groups exhibited lower DC and R(p)(max) values than the dual-polymerizing groups (P<.001), and higher DC values at 10 minutes than at 5 minutes, only in the autopolymerizing mode. Duo-Link exhibited the highest R(p)(max) values among dual-polymerizing groups, while Lute-It and Calibra showed the lowest R(p)(max) values and the highest PC(A/D) values. Within autopolymerizing groups, Nexus 2 and Lute-It exhibited the highest R(p)(max) values, while RelyX ARC demonstrated the lowest R(p)(max) as well as the lowest PC(A/D) values. CONCLUSIONS: The DC values of all autopolymerized groups of RLAs were lower than those of the dual-polymerized RLAs, but the differences in R(p)(max) and PC(A/D) were product dependent. The DC of all products was higher at the 10-minute interval than atthe 5-minute interval, only in the autopolymerizing mode.
机译:问题陈述:对双和自动聚合树脂诱剂(RLA)的固化反应动力学的认识不足,导致临床医生低估了间接修复的咬合调整所需的护理。目的:本研究的目的是评估转化率(DC),最大聚合速率(R(p)(max))和固化潜力(自聚合相对于双聚合模式的转化率; PC) (A / D))在使用红外(IR)光谱混合RLA组分后的5分钟和10分钟内有5个可双聚合的RLA。材料和方法:评估的RLA包括Calibra,Duo-Link,Lute-It,Nexus 2和RelyX ARC。操作了RLA,并将其应用于红外光谱仪光学平台中的水平菱形元素。将材料光活化40秒(双聚合模式)或使其自聚合(自聚合模式)。使用观察聚合前后脂族与芳族峰之比变化的标准技术,计算DC,R(p)(max)和PC(A / D)。通过2次重复测量方差分析和Tukey事后检验(alpha = .05)分析数据(n = 5)。结果:仅在自聚合模式下,所有自聚合基团均比双聚合基团表现出更低的DC和R(p)(max)值(P <.001),并且10分钟时的DC值高于5分钟时的DC(R)(p)(max)。 Duo-Link在双聚合组中显示出最高的R(p)(max)值,而Lute-It和Calibra显示出最低的R(p)(max)值和最高PC(A / D)值。在自聚合基团中,Nexus 2和Lute-It表现出最高的R(p)(max)值,而RelyX ARC表现出最低的R(p)(max)以及最低的PC(A / D)值。结论:所有RLA自聚合基团的DC值均低于双聚合RLA,但R(p)(max)和PC(A / D)的差异取决于产物。仅在自动聚合模式下,所有产品的DC在10分钟间隔内均高于5分钟间隔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号