STATEMENT OF PROBLEM: The success of most non-implant-retained extraoral prostheses depends on retention derived from skin adhesives. Part 1 of this study found that Skin-Prep Protective Dressing improved the retentive properties of adhesives and that Secure(2) Medical Adhesive was stronger than Epithane-3. Part 2 investigates the application of a second layer of adhesive to the prosthesis, which was earlier noted to improve retention at later time periods. PURPOSE: This study measured the force needed to remove silicone elastomer strips with Secure(2) Medical Adhesive from the skin of human subjects. Testing was performed before and after the removal of the strips and reapplication of the adhesive. MATERIAL AND METHODS: Secure(2) Medical Adhesive was painted on silicone rubber strips and placed in a nonsequential random order of the 3 variables to 3 sites on the ventral forearms of 21 human subjects and tested over an 8-hour period. The bond strength was measured at 0, 4, and 8 hours. After a reapplication of adhesive over the existing adhesive, additional bond strength measurements were made at 4 and 8 hours. Testing was at 10 cm/min in an Instron. All subjects had Skin-Prep coating applied before adhesive application. RESULTS: Bond strengths for both single applications and reapplications of the adhesive were greater at 0 hours and became significantly weaker after the 4- and 8-hour periods. The second application of the adhesive produced the strongest bonds when measured at 4 hours (110 N/m). Bonding was significantly higher at 8 hours if a second application of adhesive was applied at 0 or 4 hours. CONCLUSION: The results of this study indicate that the bond strength of silicone elastomer to skin decreased over an 8-hour interval. After removal of the silicone rubber strip and reapplication of Secure(2) Medical Adhesive over the existing adhesive, bond strengths increased.
机译:问题陈述:大多数非植入物保留的口腔外修复物的成功取决于皮肤粘合剂的保留作用。这项研究的第1部分发现Skin-Prep防护敷料改善了胶粘剂的保持性能,并且Secure(2)医用胶粘剂比Epithane-3强度更高。第2部分研究了第二层粘合剂在假体上的应用,前面提到该方法可以在以后的时间里提高保持力。目的:本研究测量了用Secure(2)医用粘合剂从人的皮肤上去除有机硅弹性体带所需的力。在去除条带和重新施加粘合剂之前和之后进行测试。材料和方法:将Secure(2)医用胶粘剂涂在硅橡胶条上,以3个变量至21个前臂腹侧3个部位的3个变量的非顺序随机顺序放置,并在8小时内进行测试。在0、4和8小时测量粘合强度。在现有粘合剂上重新涂上粘合剂后,在4和8小时进行额外的粘合强度测量。在Instron中以10 cm / min的速度进行测试。所有受试者在施胶之前都涂有Skin-Prep涂层。结果:胶粘剂的单次施用和再施用的结合强度在0小时都更高,而在4和8小时后则明显变弱。当在4小时(110 N / m)下测量时,粘合剂的第二次施加产生最强的粘结力。如果在0或4小时内第二次施加粘合剂,则在8小时时粘合力会更高。结论:这项研究的结果表明,有机硅弹性体与皮肤的粘合强度在8小时内下降。除去硅橡胶条并在现有粘合剂上重新应用Secure(2)医用粘合剂后,粘合强度提高了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号