Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis-Based Randomized Split-Mouth Clinical Trial

机译:种植体设计会影响种植体的基本稳定性吗?基于共振频率分析的随机裂口临床试验

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to assess implant stability in relation to implant design (conical vs. semiconical and wide-pitch vs narrowpitch) using resonance frequency analysis. Twenty patients with bilateral edentulous maxillary premolar region were selected. In one hemiarch, conical implants with wide pitch (group 1) were installed; in the other hemiarch, semiconical implants with narrow pitch were installed (group 2). The implant allocation was randomized. The implant stability quotient (ISQ) was measured by resonance frequency analysis immediately following implant placement to assess primary stability (time 1) and at 90 days after placement (time 2). In group 1, the mean and standard deviation ISQ for time 1 was 65.8 +/- 6.22 (95% confidence interval [CI], 55 to 80), and for time 2, it was 68.0 +/- 5.52 (95% CI, 57 to 77). In group 2, the mean and standard deviation ISQ was 63.6 +/- 5.95 (95% CI, 52 to 78) for time 1 and 67.0 +/- 5.71 (95% CI, 58 to 78) for time 2. The statistical analysis demonstrated significant difference in the ISQ values between groups at time 1 (P = .007) and no statistical difference at time 2 (P = .54). The greater primary stability of conical implants with wide pitch compared with semiconical implants with narrow pitch might suggest a preference for the former in case of the adoption of immediate or early loading protocols.
机译:这项研究的目的是使用共振频率分析评估与种植体设计(圆锥形与半圆锥形以及宽螺距与窄螺距)相关的植入物稳定性。选择20例双侧无牙上颌前磨牙区患者。在一个半主动脉中,安装了具有宽螺距的圆锥形植入物(第1组)。在另一半掌中,安装了节距较窄的半圆锥形植入物(第2组)。植入物分配是随机的。植入后立即通过共振频率分析测量植入物稳定性商(ISQ),以评估主要稳定性(时间1)和放置后90天(时间2)。在第1组中,时间1的平均和标准偏差ISQ为65.8 +/- 6.22(95%置信区间[CI],为55至80),时间2为68.0 +/- 5.52(95%CI, 57至77)。在第2组中,时间1的平均和标准偏差ISQ为63.6 +/- 5.95(95%CI,52至78),时间2为67.0 +/- 5.71(95%CI,58至78)。证实在时间1时各组之间的ISQ值存在显着差异(P = .007),在时间2无统计学差异(P = .54)。与采用窄节距的半圆锥形植入物相比,采用宽节距的圆锥形植入物具有更高的基本稳定性,这可能表明在采用立即或早期加载方案的情况下,首选后者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号