首页> 外文期刊>The Journal of Nuclear Medicine >Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.
【24h】

Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

机译:同时采集多层PET和MR图像:MR兼容PET扫描仪的初步结果。

获取原文
获取原文并翻译 | 示例
           

摘要

PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS: The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. RESULTS: PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. CONCLUSION: The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.
机译:PET和MRI是强大的成像技术,它们所提供的信息在很大程度上是互补的。我们基于雪崩光电二极管技术设计并制造了与MR兼容的PET扫描仪,该扫描仪可以同时采集小动物的PET和MR图像。方法:PET扫描仪插件使用对磁场不敏感,对位置敏感的雪崩光电二极管(PSAPD)检测器,该检测器通过短长度的光纤与正硅酸lut(LSO)闪烁体晶体阵列耦合。光纤用于最大程度地减少射频线圈和梯度线圈与PET检测器系统之间的电磁干扰。描述了PET检测器模块的组件和完整的PET插入组件。在运行和不运行MR序列的情况下获取PET数据,并将检测器洪水直方图与从磁体外部获取的数据生成的数据进行比较。还对均匀的MR体模成像,以评估PET检测器对MR数据采集的影响。离体小鼠同时进行PET和MRI研究。结果:PSAPDs可成功用于读取通过能量耦合,在能量,时序分辨率和晶体识别方面具有可接受性能的闪烁体晶体。 PSAPD-LSO检测器在7-T磁体中表现良好,并且使用标准脉冲序列在MR图像中未检测到可见的伪像。结论:已成功获取并重建了完整系统的第一批图像,这表明同时进行PET和MRI研究是可行的,并为双模态分子成像研究开辟了有趣的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号