首页> 外文期刊>The Journal of Nuclear Medicine >Preliminary Evaluation of a Fuzzy Logic-Based Automatic Quantitative Analysis in Myocardial SPECT.
【24h】

Preliminary Evaluation of a Fuzzy Logic-Based Automatic Quantitative Analysis in Myocardial SPECT.

机译:心肌SPECT中基于模糊逻辑的自动定量分析的初步评估。

获取原文
获取原文并翻译 | 示例
           

摘要

This study validates a new quantitative myocardial perfusion SPECT software. METHODS: The processing starts with the extraction of the morphologic skeleton of the left ventricular myocardium from reconstructed transverse sections. Fuzzy logic is used to decide whether a pixel belongs to the myocardium and any perfusion defect is filled according to a truncated bullet model. The resulting image is partitioned in 18 isovolumetric sectors. Sex-matched normal limits, criteria of abnormality for rest (201)Tl and (99m)Tc-labeled perfusion tracers, reproducibility studies, and detection of coronary artery disease were developed and validated in an overall population of 343 patients. The sex- and tracer-matched means and SDs of a normal response were calculated in 93 male and 93 female patients with a <5% likelihood of coronary artery disease. Reproducibility measurements and assignment of different sectors of the myocardium to a specific coronary were performed from data collected in 49 and 60 patients, respectively. The accuracy of the detection of a coronary artery occlusion was assessed in 48 patients who also underwent coronary angiography. RESULTS: The intra- and interoperator reproducibility of the sectorial activity was high with a linear regression coefficient of 0.97 and a SD of the difference measurement at 4.4% and 3.8%, respectively. Overall sensitivity and specificity for the detection of occluded coronary artery were 90% and 80%, respectively. For the detection of left anterior descending, left circumflex, and right artery coronary occlusion, sensitivity was 92%, 75%, and 92.5%, respectively, and specificity was 75%, 78%, and 90%, respectively. CONCLUSION: The new quantitative myocardial perfusion SPECT software appears to be a very helpful program for the objective analysis of perfusion tracer distribution in myocardial SPECT and a very accurate tool in the detection and localization of coronary artery occlusion.
机译:这项研究验证了一种新的定量心肌灌注SPECT软件。方法:处理始于从重建的横断面提取左心室心肌的形态骨架。模糊逻辑用于根据截短的子弹模型确定像素是否属于心肌,是否填充了任何灌注缺陷。生成的图像分为18个等体积扇区。性别匹配的正常限值,静息(201)T1和(99m)Tc标记的灌注示踪剂的异常标准,可重复性研究以及冠状动脉疾病的检测已在343名患者中进行了验证。在93名男性和93名女性冠心病可能性小于5%的患者中,计算了性别和示踪剂匹配的均值和SD的正常反应。分别从49位和60位患者收集的数据中进行了可重复性测量,并将心肌的不同区域分配给特定冠状动脉。在48例同时接受了冠状动脉造影的患者中,评估了冠状动脉闭塞的检测准确性。结果:部门活动的内部和互操作性的重现性很高,线性回归系数为0.97,差异测量的标准差分别为4.4%和3.8%。用于检测冠状动脉闭塞的总体敏感性和特异性分别为90%和80%。对于左前降支,左旋支和右动脉冠状动脉闭塞的检测,灵敏度分别为92%,75%和92.5%,特异性分别为75%,78%和90%。结论:新的定量心肌灌注SPECT软件似乎是对心肌SPECT灌注示踪剂分布的客观分析非常有用的程序,并且是检测和定位冠状动脉闭塞的非常准确的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号