...
首页> 外文期刊>The Journal of Nuclear Medicine >99mTc-cAbVCAM1-5 imaging is a sensitive and reproducible tool for the detection of inflamed atherosclerotic lesions in mice
【24h】

99mTc-cAbVCAM1-5 imaging is a sensitive and reproducible tool for the detection of inflamed atherosclerotic lesions in mice

机译:99mTc-cAbVCAM1-5成像是检测小鼠炎症性动脉粥样硬化病变的灵敏且可重复的工具

获取原文
获取原文并翻译 | 示例
           

摘要

99mTc-cAbVCAM1-5, a single-domain antibody fragment directed against mouse or human vascular cell adhesion molecule 1 (VCAM- 1), recently has been proposed as a new imaging agent for the detection of inflamed atherosclerotic lesions. Indeed, in a mouse model of atherosclerosis, 99mTc-cAbVCAM1-5 specifically bound to VCAM- 1-positive lesions, thereby allowing their identification on SPECT images. The purpose of the present study was to investigate 99mTccAbVCAM1- 5 imaging sensitivity using a reference statin therapy.Methods: Thirty apolipoprotein E-deficient mice were fed a westerntype diet. First, the relationship between the level of VCAM-1 expression and 99mTc-cAbVCAM1-5 uptake was evaluated in 18 mice using immunohistochemistry and autoradiography. Second, longitudinal SPECT/CT imaging was performed on control (n = 9) or atorvastatintreated mice (0.01% w/w, n = 9).Results: 99mTc-cAbVCAM1-5 uptake in atherosclerotic lesions correlated with the level of VCAM-1 expression (P 0.05). Atorvastatin exerted significant antiatherogenic effects, and 99mTc-cAbVCAM1-5 lesion uptake was significantly reduced in 35-wk-old atorvastatin-treated mice, as indicated by ex vivo γ-well counting and autoradiography (P 0.05). SPECT imaging quantification based on contrast-enhanced CT was reproducible (interexperimenter intraclass correlation coefficient, 0.97; intraexperimenter intraclass correlation coefficient, 0.90), and yielded results that were highly correlated with tracer biodistribution (r = 0.83; P 0.0001). Therefore, reduced 99mTc-cAbVCAM1-5 uptake in atorvastatin-treated mice was successfully monitored noninvasively by SPECT/CT imaging (0.87 ± 0.06 vs. 1.11 ± 0.09 percentage injected dose per cubic centimeter in control group, P 0.05).Conclusion: 99mTccAbVCAM1- 5 imaging allowed the specific, sensitive, and reproducible quantification of VCAM-1 expression in mouse atherosclerotic lesions. 99mTc-cAbVCAM1-5 therefore exhibits suitable characteristics for the evaluation of novel antiatherogenic agents.
机译:99mTc-cAbVCAM1-5是一种针对小鼠或人血管细胞粘附分子1(VCAM-1)的单域抗体片段,最近已被提议作为检测发炎的动脉粥样硬化病变的新成像剂。实际上,在动脉粥样硬化的小鼠模型中,99mTc-cAbVCAM1-5与VCAM-1阳性病变特异性结合,从而可以在SPECT图像上对其进行识别。本研究的目的是使用他汀类药物参考疗法研究99mTccAbVCAM1-5的成像敏感性。方法:30只载脂蛋白E缺乏症小鼠接受西式饮食。首先,使用免疫组织化学和放射自显影技术评估了18只小鼠中VCAM-1表达水平与99mTc-cAbVCAM1-5摄取之间的关系。其次,对对照组(n = 9)或阿托伐他汀治疗的小鼠(0.01%w / w,n = 9)进行纵向SPECT / CT成像。结果:动脉粥样硬化病变中的99mTc-cAbVCAM1-5摄取与VCAM-1水平相关表达(P <0.05)。阿托伐他汀具有显着的抗动脉粥样硬化作用,离体γ-孔计数和放射自显影表明,在35周龄的阿托伐他汀治疗的小鼠中99mTc-cAbVCAM1-5损伤的摄取显着降低(P <0.05)。基于对比增强CT的SPECT成像定量是可重现的(实验间类内相关系数为0.97;实验间类内相关系数为0.90),并且得出的结果与示踪剂生物分布高度相关(r = 0.83; P <0.0001)。因此,通过SPECT / CT成像成功地无创监测了阿托伐他汀治疗的小鼠中99mTc-cAbVCAM1-5摄取的减少(对照组每立方厘米注射剂量的百分比为0.87±0.06对1.11±0.09%,P <0.05)。结论:99mTccAbVCAM1 -5次成像可对小鼠动脉粥样硬化病变中的VCAM-1表达进行特异性,灵敏和可重复的定量。因此,99mTc-cAbVCAM1-5表现出适合评估新型抗动脉粥样硬化剂的特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号