Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.
机译:用常规间断可吸收缝线(对照组,平均19.4根缝线)或单条连续无结双向带刺带刺可吸收缝线(实验组)闭合10具尸体膝盖的标准media骨内侧关节置换术。通过模拟紧张性关节血积并测量3分钟内的关节切开术渗漏,比较了关节切开术封口的水密性。对照组和实验组的平均总泄漏量分别为356 mL和89 mL(p = 0.027)。使用10个膝盖中的8个膝盖(4个用对照缝合线闭合,4个用实验缝合线闭合),再次造成紧张性血栓形成,并进行医源性缝合线破裂:在1分钟时切开近端缝合线;在2分钟时切开远端缝合线。通过测量3分钟内的总关节切开术漏泄,比较了缝线破裂的影响。对照组和实验组的平均总泄漏量分别为601 mL和174 mL(p = 0.3)。总之,使用尸体模型,单根双向带刺带刺缝合线封闭的关节置换术的水密性在统计学上比使用标准间断技术封闭的关节置换术的水密性高。样本量不足以确定两种缝合技术在缝合破裂后泄漏量是否不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号