The addition of a mobile ultra-clean exponential laminar airflow screen to conventional operating room ventilation reduces bacterial contamination to operating box levels.

机译:在常规手术室通风设备中增加了移动式超清洁指数层流滤网,可将细菌污染降低至手术室水平。

获取原文
获取原文并翻译 | 示例
       

摘要

A mobile screen producing ultra-clean exponential laminar airflow (LAF) was investigated as an addition to conventional turbulent/mixing operating room (OR) ventilation (16 air changes/h). The evaluation was performed in a small OR (50 m(3)) during 60 standardized operations for groin hernia including mesh implantation. The additional ventilation was used in 50 of the operations. The LAF passed from the foot-end of the OR table over the instrument and surgical area. Strict hygiene OR procedures including tightly woven and non-woven OR clothing were used. Sedimentation rates were recorded at the level of the patients' chests (N=60) (i.e. the air had passed the surgical team) and in the periphery of the OR. In addition bacterial air contamination was studied above the patients' chests in all 10 operations without the additional LAF and in 12 with the LAF. The screen reduced the mean counts of sedimenting bacteria (cfu/m(2)/h) on the patients' chests from 775 without the screen to 355 (P=0.0003). The screen also reduced the mean air counts of bacteria (cfu/m(3)) above the patients' chests from 27 to 9 (P=0.0001). No significant differences in mean sedimentation rates (cfu/m(2)/h) existed in the periphery of the OR where 628 without and 574 with screen were recorded. During the follow-up period of six months no surgical site infections were detected. In conclusion when the mobile LAF screen was added to conventional OR ventilation the counts of aerobic airborne and sedimenting bacteria-carrying particles downstream of the surgical team were reduced to the levels achieved with complete ultra-clean LAF OR ventilation (operating box).
机译:作为传统湍流/混合手术室(OR)通风(16换气/ h)的补充,研究了可产生超洁净指数层流(LAF)的移动筛网。该评估是在60例针对腹股沟疝的标准化手术(包括网状植入)中以较小的OR(50 m(3))进行的。 50次手术中使用了额外的通风。 LAF从“手术台”的脚端经过器械和手术区域。使用了严格的卫生或程序,包括紧密织造和无纺布或衣物。在患者胸部(N = 60)(即空气已通过手术团队)的水平和手术室周围记录了沉积率。此外,在没有附加LAF的所有10例手术中和在有LAF的12例中,对患者胸部上方的细菌性空气污染进行了研究。筛网将患者胸部的沉积细菌平均计数(cfu / m(2)/ h)从没有筛网的775减少到355(P = 0.0003)。屏幕还将患者胸部上方的细菌平均空气计数(cfu / m(3))从27降低至9(P = 0.0001)。在俄勒冈州的外围没有平均沉降速率(cfu / m(2)/ h)的显着差异,其中记录了628个无筛查和574个有筛查的情况。在六个月的随访期内,未发现手术部位感染。总而言之,当将移动式LAF筛网添加到常规OR通风中时,手术团队下游的需氧空气传播和沉积细菌携带颗粒的数量减少到了完全超净LAF OR通风(操作箱)所能达到的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号