Evaluation of non-reassuring fetal heart rate patterns with fetal pulse oximetry combined with vibratory acoustic stimulation.

机译:胎儿脉搏血氧饱和度法结合振动声刺激评估无法保证的胎儿心率模式。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: To determine the value of fetal pulse oximetry and vibratory acoustic stimulation in the presence of non-reassuring fetal heart rate patterns during labor. DESIGN: Prospective study in women monitored by cardiotocography and fetal pulse oximetry during labor. MATERIALS AND METHODS: During a period of 18 months, 907 consecutive parturients in labor were monitored by cardiotocography. Out of these women, 63 were selected on the basis of a non-reassuring fetal heart rate tracing during the first stage of labor. In these cases, fetal pulse oximetry was applied. Vibratory acoustic stimulation was applied in fetuses without spontaneous reactivity in order to evaluate the fetal status. RESULTS: Our cases were classified into three groups, according to the lower fetal oxygen saturation levels, from the time of oximetry application until delivery. Group A consisted of 29 cases where fetal oxygen saturation levels were > or = 41%, group B (20 cases) with fetal oxygen saturation of 31-40% and group C (14 cases) with levels of < 30%. Spontaneous reactivity was observed in 15 fetuses of group A and seven of group B, while no case of reactivity was noted in group C. Vibratory acoustic-induced reactivity was associated with low fetal oxygen saturation levels. The mean umbilical artery pH levels were 7.29 +/- 0.051 in group A, 7.21 +/- 0.057 in group B and 7.04 +/- 0.05 in group C. CONCLUSION: Fetal pulse oximetry should be indicated not only in fetuses without any reactivity but also in those with induced reactivity, after the application of vibratory acoustic stimulation.
机译:目的:确定在分娩时无法保证胎儿心率的情况下,胎儿脉搏血氧饱和度和振动声刺激的价值。设计:在分娩期间通过心动描记法和胎儿脉搏血氧饱和度监测的女性前瞻性研究。材料与方法:在18个月的时间内,通过心动描记法监测了907名连续分娩的产妇。在这些妇女中,根据第一胎分娩时无法保证的胎儿心率追踪结果选择了63名妇女。在这些情况下,采用胎儿脉搏血氧仪。对没有自发反应性的胎儿进行振动声刺激以评估胎儿的状况。结果:从较低的胎儿血氧饱和度水平开始,从应用血氧测定法到分娩,我们的病例分为三组。 A组由29例胎儿血氧饱和度大于或等于41%的病例组成,B组(20例)胎儿血氧饱和度为31-40%,C组(14例)胎儿血氧饱和度≤30%。在A组的15胎和B组的7胎中观察到自发反应性,而C组中未发现反应性情况。振动声诱发的反应性与低胎儿血氧饱和度有关。 A组的平均脐动脉pH值是7.29 +/- 0.051,B组的是7.21 +/- 0.057,C组的是7.04 +/- 0.05。结论:不仅在没有反应性的胎儿中还应使用胎脉血氧饱和度测定法。在使用振动声刺激后,在那些具有诱发反应性的患者中也是如此。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号