Accuracy of Digital Preoperative Templating in 100 Consecutive Uncemented Total Hip Arthroplasties. A Single Surgeon Series

机译:数字术前模板在100例连续性非骨水泥全髋关节置换术中的准确性。单一外科医生系列

获取原文
获取原文并翻译 | 示例
       

摘要

Digital templating is an accurate method of assessing femoral and acetabular component sizes. This allows surgeons to foresee potential problems and also recognize an intraoperative error when a large discrepancy exists between a trial component and the templated size. Preoperative templating data of pelvic radiographs from 100 consecutive patients receiving uncemented implants were templated with Orthoview software (version 2.0CEN; Meridian Technique Ltd, Southampton, United Kingdom). Seventy-five percent of stems were templated to within 0.5 size, and 98%, to within 1 size. Eighty percent of cups were templated to within 2 mm, and 98%, to within 4 mm, and 62% of head length was accurately template. Seven patients were converted from a templated 132?? to a 127?? femoral prosthesis neck angle. The mean lower limb length discrepancy was +. 0.05 mm (SD, 5.1 mm) postoperatively. ? 2013 Elsevier Inc.
机译:数字模板是评估股骨和髋臼组件尺寸的准确方法。当试验部件和模板尺寸之间存在较大差异时,这可以使外科医生预见潜在的问题,并可以识别术中错误。使用Orthoview软件(版本2.0CEN; Meridian Technique Ltd,南安普敦,英国)对100例接受非骨水泥植入物的连续患者的骨盆射线照相术前模板数据进行模板化。 75%的茎被模板化到0.5尺寸以内,而98%的模板被模板化至1尺寸。 80%的杯子被模板化到2毫米以内,98%的杯子被模板化到4毫米以内,并且62%的头部长度被精确地模板化。从模板化的132位患者中转换了7位患者。到127?股骨假体颈部角度。下肢平均长度差异为+。术后0.05 mm(SD,5.1 mm)。 ? 2013爱思唯尔公司

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号