We analyzed the results of 206 consecutive total hip arthroplasties performed using large diameter ceramic-on-ceramic bearings. At an average follow-up of 28 months, the mean Harris Hip Score improved from 54 to 92. Fifteen (7.3%) hips were noted to squeak. There was no significant difference between silent and squeaking hips with regards to age, weight, height, BMI, range of movement, femoral head diameter, leg length, and offset or center of rotation. No correlation was present between incidence of squeaking and increasing cup inclination and anteversion. 5.2% of cups orientated within Lewinnek's safe zone squeaked. No hips required revision for squeaking. While large diameter ceramic bearings may produce squeaking, our early results of surgery using large head ceramic bearings are encouraging. However, long-term follow-up is required. (C) 2014 Elsevier Inc. All rights reserved.
机译:我们分析了使用大直径陶瓷-陶瓷轴承进行的206次连续全髋关节置换术的结果。平均随访28个月,Harris髋关节平均得分从54分提高到92分。发现有15髋(7.3%)发出吱吱声。在年龄,体重,身高,BMI,活动范围,股骨头直径,腿长以及偏移或旋转中心方面,无声和吱吱的臀部之间没有显着差异。吱吱声的发生与杯倾斜和前倾的增加之间没有相关性。 5.2%的杯子在Lewinnek的安全区域内吱吱作响。臀部不需翻修。虽然大直径陶瓷轴承可能会产生吱吱声,但我们使用大头陶瓷轴承的早期手术结果令人鼓舞。但是,需要长期随访。 (C)2014 Elsevier Inc.保留所有权利。