首页> 外文期刊>The Journal of arthroplasty >Management of Periprosthetic Joint Infection After Total Hip Arthroplasty Using a Custom Made Articulating Spacer (CUMARS); the Exeter Experience
【24h】

Management of Periprosthetic Joint Infection After Total Hip Arthroplasty Using a Custom Made Articulating Spacer (CUMARS); the Exeter Experience

机译:使用定制的关节间隙垫片(CUMARS)处理全髋关节置换术后的假体周围感染;埃克塞特体验

获取原文
获取原文并翻译 | 示例
           

摘要

Periprosthetic joint infection (PJI) after THA is a major complication with an incidence of 1%-3%. We report our experiences with a technique using a custom-made articulating spacer (CUMARS) at the first of two-stage treatment for PJI. This technique uses widely available all-polyethylene acetabular components and the Exeter Universal stem, fixed using antibiotic loaded acrylic cement. Seventy-six hips were treated for PJI using this technique. Performed as the first of a two-stage procedure, good functional results were commonly seen, leading to postponing second stage indefinitely with retention of the CUMARS prosthesis in 34 patients. The CUMARS technique presents an alternative to conventional spacers, using readily available components that are well tolerated, allowing weight bearing and mobility, and achieving comparable eradication rates. Crown Copyright (C) 2014 Published by Elsevier Inc.
机译:THA后假体周围感染(PJI)是主要并发症,发生率1%-3%。我们在PJI的两阶段治疗中的第一阶段报告了使用定制关节间隔器(CUMARS)的技术的经验。这项技术使用了广泛可用的全聚乙烯髋臼组件和Exeter Universal杆,该杆使用抗生素加载的丙烯酸水泥固定。使用该技术对76例髋关节进行了PJI治疗。作为两阶段手术的第一步,通常可以看到良好的功能结果,导致34例患者因保留CUMARS假体而无限期推迟第二阶段的手术​​。 CUMARS技术提供了一种常规垫片的替代品,它使用了易于耐受的易于使用的组件,可以承重和移动,并且达到了可比的铲除率。官方版权(C)2014,由Elsevier Inc.发行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号