首页> 外文期刊>The Journal of arthroplasty >The Protective Effect of Pulsed Lavage Against Implant Subsidence and Micromotion for Cemented Tibial Unicompartmental Knee Components: An Experimental Cadaver Study
【24h】

The Protective Effect of Pulsed Lavage Against Implant Subsidence and Micromotion for Cemented Tibial Unicompartmental Knee Components: An Experimental Cadaver Study

机译:脉冲灌洗对骨水泥胫骨单室膝关节假体下陷和微动的保护作用:实验尸体研究

获取原文
获取原文并翻译 | 示例
           

摘要

Cemented UKAs were performed in 12 pairs of human cadaver legs and the bone bed was cleansed using pulsed lavage (group A) and conventional syringe lavage (group B). Subsidence and micromotion of the loaded tibial trays were measured. There was a significant effect of BMD on subsidence (P=0.043) but not on micromotion. Cement penetration of group A was significantly increased (P=0.005). Group A showed a reduced implant subsidence (P=0.025) and micromotion (P=0.026) compared to group B. The group differences in micromotion and implant subsidence of UKA tibial components were statistically significant but rather small and might clinically be of minor importance. Nevertheless a worse bone quality adversely affected implant subsidence and pulsed lavage had a protective effect in these specimens.
机译:在12对人的尸体腿中进行胶结的UKA,并使用脉冲灌洗(A组)和常规注射器灌洗(B组)清洁骨床。测量胫骨托的下沉和微动。 BMD对下沉有显着影响(P = 0.043),但对微动没有影响。 A组的水泥渗透率显着增加(P = 0.005)。与B组相比,A组的种植体下陷(P = 0.025)和微动(P = 0.026)减少。UKA胫骨组件的微运动和种植体下沉的组差异具有统计学意义,但相当小,在临床上可能次要。然而,较差的骨骼质量对植入物沉陷产生了不利影响,脉冲灌洗对这些标本具有保护作用。