首页> 外文期刊>The Journal of arthroplasty >Outcomes After Revision of Metal-on-Metal Hip Resurfacing Arthroplasty
【24h】

Outcomes After Revision of Metal-on-Metal Hip Resurfacing Arthroplasty

机译:金属-金属髋关节置换置换术后的结果

获取原文
获取原文并翻译 | 示例
           

摘要

We report the results of 58 hip resurfacing arthroplasties (HRA) revised by a single surgeon with an average of 5.2 +/- 2.6 years follow-up. The four most common causes for revision were acetabular component loosening, femoral neck fracture, femoral component loosening, and adverse wear related failure (AWRF). In 95% of cases (55/58), the revision bearing was a large metal-on-metal type including all seven AWRF cases; three cases were revised to ceramic-on-polyethylene. There were two repeat revisions due to acetabular component loosening. Revision of AWRF had an excellent outcome using limited debridement and a stable large metal bearing placed in the correct position. The only problematic group was the one revised for acetabular loosening in which 2/16 (6%) required repeat revision for failure of acetabular fixation. (C) 2014 Elsevier Inc. All rights reserved.
机译:我们报告了由一名外科医生修订的58例髋关节置换术(HRA)的结果,平均随访5.2 +/- 2.6年。翻修的四个最常见原因是髋臼组件松动,股骨颈骨折,股骨组件松动和与磨损相关的不良衰竭(AWRF)。在95%的情况下(55/58),修正轴承是大型金属对金属轴承,包括所有七个AWRF情况;三例被修改为聚乙烯陶瓷。由于髋臼组件松动,有两次重复修订。使用有限的清创术和将稳定的大型金属轴承放置在正确的位置,对AWRF的修订具有出色的效果。唯一有问题的组是修订后的髋臼松动组,其中2/16(6%)的患者因髋臼固定失败而需要再次修订。 (C)2014 Elsevier Inc.保留所有权利。