Patients with peri-acetabular osteolysis around a well fixed cementless acetabular component may be treated with liner exchange. When the locking mechanism is unreliable or unavailable, cementing the liner into the fixed acetabular component is a feasible option. The purpose of this study was to evaluate the clinical and radiographic long term results of this technique. Forty hip revisions with liner cementation in 37 patients were performed. The minimum follow up was 10 years. Modified Harris Hip Score and recent x rays were reviewed. Four hips were re-revised. Two patients were diagnosed with exacerbation of osteolysis but refused revision. Dislocation rate was relatively high (16%). Liner cementation technique in revision hip surgery is useful in patients with a well fixed metal backed acetabular component. (C) 2015 Elsevier Inc. All rights reserved.
机译:在固定良好的非骨水泥髋臼组件周围发生髋臼周围骨溶解的患者可以进行衬管置换治疗。当锁定机构不可靠或不可用时,将内衬固定在固定的髋臼组件中是可行的选择。这项研究的目的是评估该技术的临床和放射学长期结果。对37例患者进行了40次髋关节内膜固定术。最小随访时间为10年。修改的哈里斯髋关节评分和最近的X射线进行了审查。四个臀部被重新修订。两名患者被诊断出骨溶解加剧,但拒绝翻修。脱位率相对较高(16%)。髋关节翻修术中的衬里胶合技术对固定有金属衬托的髋臼组件的患者很有用。 (C)2015 Elsevier Inc.保留所有权利。