Extra-large press-fit cups without screws for acetabular revision.

机译:不带螺丝的超大型压配合杯,用于髋臼翻修。

获取原文
获取原文并翻译 | 示例
       

摘要

This retrospective study reports the 4- to 6-year results of clinical and radiologic follow-up of 60 acetabular revisions using extra-large hemispherical press-fit cups without additional screw fixation. Bone grafts were used in 17 cases. One cup loosened and required re-revision after 12 months. Initial migration was noted in 6 cases, but showed no progression after less than 2 years. In 2 hips that were revised for deep infection, the cups were found incorporated. At final follow-up, 57 hips (95%) were found firmly fixed radiologically. The Harris Hip score improved from a mean of 58.7 points preoperatively to 90.6 points. Provided a high friction coefficient is present, extra-large hemispherical cups offer sufficient stability even in severe cases. Most do not require additional screw fixation.
机译:这项回顾性研究报告了使用超大半球压入配合杯而不需额外螺钉固定的60例髋臼翻修的临床和放射学随访4至6年的结果。骨移植17例。松开一个杯子,并在12个月后需要重新修订。注意到有6例初次迁移,但在不到2年的时间内没有进展。在为深部感染而修订的2个髋部中,发现合并了这些杯子。在最后的随访中,发现在放射学上已牢固固定了57髋(95%)。 Harris Hip评分从术前平均58.7分提高到90.6分。如果存在高摩擦系数,则即使在严重的情况下,超大半球形杯也可以提供足够的稳定性。大多数不需要额外的螺钉固定。