首页> 外文期刊>The Journal of arthroplasty >Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.
【24h】

Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.

机译:急性全髋关节置换术用电缆稳定髋臼骨折。

获取原文
获取原文并翻译 | 示例
           

摘要

A critical stage of total hip arthroplasty for an acute acetabular fracture where extensive comminution, impaction, and osteopenia thwart the application of conventional open or closed methods, especially in the elderly, is stable fixation of the acetabulum. The use of 2-mm braided cables permits effective immobilization of the fracture for use in conjunction with a hybrid arthroplasty. The method is consistent with the use of a conventional arthroplastic incision and is suitable for other applications including the fixation of periprosthetic fractures, bulk allografts, and conventional acetabular fractures.
机译:急性髋臼骨折的全髋关节置换的关键阶段是髋臼的稳定固定,在这种情况下,广泛的粉碎,撞击和骨质减少阻碍了传统的开放或闭合方法的应用,尤其是在老年人中。使用2毫米编织电缆可有效固定骨折,与混合型关节置换术结合使用。该方法与常规关节成形术切口的使用相一致,并且适用于其他应用,包括修复假体周围骨折,同种异体骨移植和常规髋臼骨折。