Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius.

机译:骨干physi端粉碎性骨折的微创钢板接骨术。

获取原文
获取原文并翻译 | 示例
       

摘要

Five comminuted and displaced fractures of the distal metaphysis of the radius were treated by a technique of minimally invasive plate osteosynthesis (MIPO) with the aim of minimizing soft tissue damage and devascularization of the fracture fragments. This technique used the small AO T-shaped locking compression plate (AO LCP T-plate) and left the pronator quadratus intact. Radial inclination, palmar tilt, and ulnar variance were restored without loss of reduction in all five cases and the fractures healed at an average of 10 weeks, with good to excellent clinical outcomes.
机译:minimal骨远端干physi端的五个粉碎性和移位性骨折采用微创钢板骨合成技术(MIPO)进行治疗,目的是最大程度地减少软组织损伤和骨折碎片的血运重建。这项技术使用了小的AO T形锁定压缩板(AO LCP T板),并保留了前屈肌的正交方肌。在所有五例病例中,骨倾斜度,手掌倾斜度和尺骨方差均得以恢复,且无复位降低,并且骨折平均愈合10周,具有良好的临床效果。