Current approaches to the proximal interphalangeal (PIP) joint have potential complications and limitations. We present a dorsal approach that involves splitting the extensor tendon in the midline, detaching the insertion of the central slip and repairing the extensor tendon without reinserting the tendon into the base of the middle phalanx. A retrospective review of 16 digits that had the approach for a PIP joint arthroplasty with a mean follow up of 23 months found a postoperative PIP active ROM of 61deg (range 25-90deg). Fourteen digits had no extensor lag, while two digits had an extensor lag of 20deg and 25deg. This modified approach is fast and simple and does not cause an extensor lag.
机译:当前的近端指间关节(PIP)入路有潜在的并发症和局限性。我们提出了一种背侧方法,其中包括在中线分裂伸肌腱,分离中央滑道的插入并修复伸肌腱,而无需将肌腱重新插入中指骨的底部。回顾性分析采用PIP关节置换术的16位患者,平均随访23个月,发现术后PIP活性ROM为61deg(范围为25-90deg)。 14位数字没有伸展延迟,而两位数字的伸展延迟是20度和25度。这种改进的方法既快速又简单,不会引起伸肌延迟。