首页> 外文期刊>The Japanese journal of antibiotics >Comparison of foyr reading methods of broth microdilufion based on the Clinical and Laboratory Standards Institute M27-A3 method for Candida spp.
【24h】

Comparison of foyr reading methods of broth microdilufion based on the Clinical and Laboratory Standards Institute M27-A3 method for Candida spp.

机译:根据临床和实验室标准协会M27-A3念珠菌方法对肉汤微量稀释的foyr读取方法的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study aimed to compare the susceptibilities of 5 reference strains and 28 isolates of Candida spp., to micafungin, amphotericin B, flucytosine, fluconazole, itraconazole, voriconazole, and miconazole, obtained by visually determined minimum inhibitory concentration (MIC) using the agitation method (V-A), as described in the Clinical and Laboratory Standards Institute M27-A3 document; visual determinations without agitation (V-NA); and spectrophotometric determinations for the presence or absence of agitation (SP-A and SP-NA, respectively). Our results indicate that when the V-NA, SP-A, and SP-NA-the 3 alternative microdilution procedures for MIC endpoint determinations-were compared with the V-A, excellent agreements were observed between the V-NA and V-A rather than with the spectrophotometric methods (between the SP-A or SP-NA, and V-A). Furthermore, many errors occurred while using the SP-A method in the presence of agitation and some isolates showed major errors. Three of 5 isolates that showed very major errors between the spectrophotometric SP-A or SP-NA, and the reference V-A method were trailing isolates. Therefore, it was suggested that the MICs of Candida spp. obtained by the V-NA method were more precise than those by the conventional SP-A method.
机译:这项研究旨在比较5种参考菌株和28株假丝酵母菌对米卡芬净,两性霉素B,氟胞嘧啶,氟康唑,伊曲康唑,伏立康唑和咪康唑的敏感性,这是通过搅拌法通过目测确定的最小抑菌浓度(MIC)获得的。 (VA),如临床和实验室标准协会M27-A3文件中所述;目视测定,无需搅拌(V-NA);和分光光度法测定是否存在搅拌(分别为SP-A和SP-NA)。我们的结果表明,当将V-NA,SP-A和SP-NA(用于MIC终点测定的3种备选微量稀释方法)与VA进行比较时,在V-NA和VA之间观察到了极好的协议,而不是与VA相比。分光光度法(在SP-A或SP-NA与VA之间)。此外,在搅拌下使用SP-A方法时,发生了许多错误,某些分离株显示出重大错误。在分光光度法SP-A或SP-NA与参考V-A方法之间显示非常重大误差的5个分离株中,有3个是尾随分离株。因此,建议使用假丝酵母的MIC。通过V-NA方法获得的结果比通过常规SP-A方法获得的结果更精确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号