...
首页> 外文期刊>The journal of adhesive dentistry >Percentage exposure of root dentin collagen after application of two irrigation protocols with manual or rotary instrumentation and two methacrylate resin-based sealers.
【24h】

Percentage exposure of root dentin collagen after application of two irrigation protocols with manual or rotary instrumentation and two methacrylate resin-based sealers.

机译:应用手动或旋转仪器的两种冲洗方案和两种基于甲基丙烯酸酯树脂的密封剂后,根部牙本质胶原蛋白的暴露百分比。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

To compare the percentage of collagen exposed in dentin root thirds after two irrigation protocols with manual or rotary instrumentation using two methacrylate resin-based sealers.Forty-eight single-root human teeth were prepared with manual (n = 24) or nickeltitanium ProFile rotary (n = 24) instrumentation, using 5% NaOCl between instruments and 5 ml 17% EDTA as final irrigant or 20% citric acid + 2% chlorhexidine (CHX) between instruments and as the final irrigant. RealSeal or EndoREZ were used as filling materials. One 1-mm slice per third was abraded and stained with Masson's trichrome method. Mean exposed collagen values were obtained in four areas from each section (at 60X magnification) and a complete factorial ANOVA was used to analyze the influence of the study variables. Non-parametric Mann-Whitney's test was used to compare groups. Differences with p < 0.05 were considered significant.A significantly higher percentage of collagen was exposed in all thirds with the use of the 20% citric acid + 2% CHX protocol with rotary vs manual instrumentation, but percent collagen exposed did not differ as a function of the filling material. After the 5% NaOCl + 17% EDTA protocol, the percentage of collagen exposed did not differ between rotary and manual instrumentation but was higher with the use of RealSeal.The highest percentage exposure of collagen was with 20% citric acid + 2% CHX using rotary instrumentation, regardless of the filling material.
机译:为了比较使用两种基于甲基丙烯酸酯树脂的封闭剂通过手动或旋转器械进行两次冲洗后,牙本质牙根中三分之一暴露的胶原蛋白的百分比。使用手动(n = 24)或镍钛合金ProFile旋转制备了48颗单根人牙( n = 24)仪器,使用仪器之间的5%NaOCl和5 ml 17%EDTA作为最终冲洗剂,或使用20%柠檬酸+ 2%洗必太(CHX)作为最终冲洗剂。 RealSeal或EndoREZ用作填充材料。三分之一的1毫米切片被磨擦并用Masson的三色染色法染色。在每个区域的四个区域(放大60倍)获得平均暴露的胶原蛋白值,并使用完整的阶乘方差分析来分析研究变量的影响。使用非参数Mann-Whitney检验来比较组。 p <0.05的差异被认为是显着的。在20%柠檬酸+ 2%CHX方案与旋转器械与手动器械相比下,所有三分之二的胶原蛋白暴露百分比均显着更高,但胶原蛋白暴露百分比随功能的变化没有差异填充材料。在5%NaOCl + 17%EDTA方案后,旋转和手动仪器之间的胶原蛋白暴露百分比没有差异,但使用RealSeal更高;胶原蛋白的最高暴露百分比是20%柠檬酸+ 2%CHX旋转仪表,而不考虑填充材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号