首页> 外文期刊>The British Journal of Nutrition >Validity and reliability of body composition analysers in children and adults.
【24h】

Validity and reliability of body composition analysers in children and adults.

机译:儿童和成人人体成分分析仪的有效性和可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

We tested the validity and reliability of the BioSpace InBody 320, Omron and Bod-eComm body composition devices in men and women (n 254; 21-80 years) and boys and girls (n 117; 10-17 years). We analysed percentage body fat (%BF) and compared the results with dual-energy X-ray absorptiometry (DEXA) in adults and compared the results of the InBody with underwater weighing (UW) in children. All body composition devices were correlated (r 0.54-0.97; P< or =0.010) to DEXA except the Bod-eComm in women aged 71-80 years (r 0.54; P=0.106). In girls, the InBody %BF was correlated with UW (r 0.79; P< or =0.010); however, a more moderate correlation (r 0.69; P< or =0.010) existed in boys. Bland-Altman plots indicated that all body composition devices underestimated %BF in adults (1.0-4.8 %) and overestimated %BF in children (0.3-2.3 %). Lastly, independent t tests revealed that the mean %BF assessed by the Bod-eComm in women (aged 51-60 and 71-80 years) and in the Omron (age 18-35 years) were significantly different compared with DEXA (P< or =0.010). In men, the Omron (aged 18-35 years), and the InBody (aged 36-50 years) were significantly different compared with DEXA (P=0.025; P=0.040 respectively). In addition, independent t tests indicated that the InBody mean %BF in girls aged 10-17 years was significantly different from UW (P=0.001). Pearson's correlation analyses demonstrated that the Bod-eComm (men and women) and Omron (women) had significant mean differences compared with the reference criterion; therefore, the %BF output from these two devices should be interpreted with caution. The repeatability of each body composition device was supported by small CV (<3.0 %).
机译:我们测试了BioSpace InBody 320,Omron和Bod-eComm人体成分仪在男性和女性(n 254; 21-80岁)和男孩和女孩(n 117; 10-17岁)中的有效性和可靠性。我们分析了成人的体脂百分比(%BF),并将结果与​​成人双能X线骨密度仪(DEXA)进行了比较,并将InBody的结果与儿童的水下称重(UW)进行了比较。除Bod-eComm年龄在71-80岁的女性外,所有身体成分的设备都与DEXA相关(r 0.54-0.97; P <或= 0.010)(r 0.54; P = 0.106)。在女孩中,InBody%BF与UW相关(r 0.79; P <或= 0.010);然而,男孩中存在更适度的相关性(r = 0.69; P <或= 0.010)。布兰德-奥特曼(Bland-Altman)图表明,所有身体组成设备均低估了成年人的%BF(1.0-4.8%),而高估了儿童的%BF(0.3-2.3%)。最后,独立的t检验显示,由Bod-eComm评估的女性(51-60岁和71-80岁)和欧姆龙(18-35岁)的平均%BF与DEXA显着不同(P <或= 0.010)。与DEXA相比,男性的Omron(年龄18-35岁)和InBody(年龄36-50岁)有显着差异(分别为P = 0.025; P = 0.040)。此外,独立的t检验表明,10-17岁女孩的InBody平均%BF与UW显着不同(P = 0.001)。皮尔森(Pearson)的相关性分析表明,与参考标准相比,Bod-eComm(男女)和Omron(妇女)的均值差异显着。因此,应谨慎解释这两个设备的%BF输出。较小的CV(<3.0%)支持每个人体组成设备的重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号