Intercomparison experiments with electrical strain gages and optical fibre Bragg strain sensors were performed in both, tensile strain and bending configurations for 14 FBG sensors at room temperature. In a total of 53 quasi-static load tests the strain sensitivities of the FBG sensors were found to be reproducible in the order of 0.5percent. The FBG strain sensors showed a mean strain sensitivity of k velence 0.792+-0.016, employing the electrical strain gages as reference strain sensors.
机译:在室温下,对14个FBG传感器的拉伸应变和弯曲配置,均进行了电应变计和光纤布拉格应变传感器的比对实验。在总共53个准静态负载测试中,发现FBG传感器的应变灵敏度可重现0.5%左右。 FBG应变传感器采用电应变计作为参考应变传感器,显示出平均应变灵敏度为kvelence 0.792 + -0.016。