首页> 外文期刊>The American Journal of Medicine >Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring
【24h】

Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring

机译:比较24小时动态心电图监测与14天新型胶粘剂心电图监测

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration-cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. Methods: A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar's tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. Results: Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P <.001). Conclusions: Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring.
机译:背景:心脏心律失常非常常见,通常由于暂时性和无症状而无法诊断。有效的诊断和治疗可以大大降低与心律不齐相关的发病率和死亡率。 Zio贴片(iRhythm Technologies,Inc,加利福尼亚州旧金山)是一种新型的单导心电图(ECG),轻巧,经食品药品监督管理局(FDA)批准,可连续记录的动态记录贴片监护仪,适用于在所推荐患者中检测心律不齐动态心电图监测。方法:总共146名接受评估的心律不齐的患者接受了常规24小时动态心电图监护仪和14天胶粘剂斑块监护仪同时进行动态心电图记录。该研究的主要结果是比较两种设备在整个佩戴时间内的检测到的心律失常事件。心律失常事件被定义为检测到6种心律失常中的任何一种,包括室上性心动过速,房颤/颤动,停顿大于3秒,房室传导阻滞,室性心动过速或多形性室性心动过速/室性心律失常。麦克尼玛(McNemar)的测试用于比较来自动态心电图(Holter)和粘性贴片监视器的配对数据。结果:在两个设备的总佩戴时间上,粘性贴片监视器检测到96个心律不齐事件,而Holter监视器则检测到61个心律不齐事件(P <.001)。结论:在这两种设备的总佩戴时间上,胶布贴片监视器比动态心电图监视器检测到更多事件。使用单导联,不太引人注目的,胶粘剂贴片的监测平台进行长时间的心律失常事件监测可以代替常规的动态心电图监测,用于需要动态ECG监测的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号