A novel tetrachlorothallate (III) (TCT)-selective membrane sensor consisting of tetrachlorothallate (III)-2,3,5-triphenyl-2-H-tetrazolium ion pair dispersed in a PVC matrix plasticized with diocylphthalate is described. The electrode shows a stable, near-Nernstian response for 1 * 10~(-3)-4 * 10~(-6) M thallium (III) at 25 ℃ with an anionic slope of 56.5±0.5 over the pH range 3-6. The lower detection limit and the response time are 2 * 10~9-6) M and 30-60 s, respectively. Selectivity coefficients for Tl(III) relative to a number of interfering substances were investigated. There is negligible interference from many cations and anions; however, iodide and bromide are significantly interfere. The determination of 0.5-200 μg ml~(-1) of Tl(III) in aqueous solutions shows an average recovery of 99.0% and a mean relative standard deviation of 1.4% at 50.0 μg ml~(-1). The direct determination of Tl(III) in spiked wastewater gave results that compare favorably with those obtained by the atomic abosprtion spectrometric method. The electrode was successfully applied for the determination of thallium in zinc concentrate. Also the tetrachlorothallate electrode has been utilized as an end point indicator electrode for the determination of thallium using potentiometric titration.
机译:描述了一种新型的四氯thallate(III)(TCT)-选择性膜传感器,该传感器由四氯thallate(III)-2,3,5-三苯基-2-H-四唑鎓离子对组成,分散在用邻苯二甲酸二辛酯增塑的PVC基质中。电极在25℃下对1 * 10〜(-3)-4 * 10〜(-6)M al(III)表现出稳定的近能斯特响应,在pH范围3-上的阴离子斜率为56.5±0.5。 6。检测下限和响应时间分别为2 * 10〜9-6)M和30-60 s。研究了Tl(III)相对于多种干扰物质的选择性系数。许多阳离子和阴离子的干扰可忽略不计;但是,碘化物和溴化物会显着干扰。水溶液中Tl(III)的0.5-200μgml〜(-1)的测定表明,在50.0μgml〜(-1)时,平均回收率为99.0%,平均相对标准偏差为1.4%。直接测定加标废水中的Tl(III)所得到的结果与原子吸收光谱法获得的结果相称。该电极已成功用于锌精矿中determination的测定。四氯乙磺酸盐电极也已被用作通过电位滴定法测定th的终点指示电极。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号