...
首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Evaluation of immobilized redox indicators as reversible, in situ redox sensors for determining Fe(III)-reducing conditions in environmental samples
【24h】

Evaluation of immobilized redox indicators as reversible, in situ redox sensors for determining Fe(III)-reducing conditions in environmental samples

机译:固定化氧化还原指示剂作为可逆的原位氧化还原传感器的评估,用于确定环境样品中的Fe(III)还原条件

获取原文
获取原文并翻译 | 示例

摘要

An in situ methodology based on immobilized redox indicators has been developed to determine when Fe(III)-reducing conditions exist in environmental systems. The redox indicators thionine (Thi, formal potential at pH 7 (E_7~(O')) equals 66 mV), toluidine blue O (TB, E_7~(O') = 31 mV) and cresyl violet (CV, E_7~(O') = -75 mV) have been immobilized to 40-60 #mu#m agarose beads via an amine-aldehyde coupling reaction. These beads were packed into a flow cell to allow spectrophotometric monitoring of the redo state of simple solutions and wastewater slurries pumped from in a bioreactor. Fe(II), a product of microbial activity, at levels observed in real systems reduces both the free (non-immobilized) and immobilized redox indicator to different degrees for samples with pH 6.5 or higher. At pH 7, immobilized Thi and TB are significantly reduced at Fe(II) concentrations greater than 0.1 and 0.3 mM, respectively. CV, with the lowest formal potential, requires Fe(II) levels in excess of 10 mM. The degree of reduction of the indicators (i.e. the fraction of indicator oxidized) observed during tittrations can be qualitatively modeled with a simple equilibrium model based on ferrihydrite or lepidocrocite as the Fe(III)-solid phase. The reversibility of Fe(II)-indicator reactions was also demonstrated by slowing that the reduced indicator becomes re-oxidized when Fe(II) levels decrease.
机译:已经开发了一种基于固定化氧化还原指标的原位方法,以确定环境系统中何时存在还原Fe(III)的条件。氧化还原指示剂亚硫氨酸(Thi,pH 7的形式势(E_7〜(O'))等于66 mV),甲苯胺蓝O(TB,E_7〜(O')= 31 mV)和甲酚紫(CV,E_7〜(通过胺-醛偶联反应将O')=-75mV)固定在40-60μμm的琼脂糖珠上。将这些珠粒填充到流通池中,以分光光度法监控简单溶液和从生物反应器中泵送的废水浆液的重做状态。 Fe(II)是微生物活性的产物,在实际系统中观察到的水平对pH 6.5或更高的样品将游离的(未固定的)和固定的氧化还原指示剂都不同程度地降低。在pH值为7时,Fe(II)浓度分别大于0.1和0.3 mM时,固定化的Thi和TB显着降低。具有最低形式势的CV需要的Fe(II)水平超过10 mM。滴定过程中观察到的指示剂的还原度(即指示剂被氧化的比例)可以使用基于水铁矿或纤铁矿为Fe(III)-固相的简单平衡模型定性建模。 Fe(II)指示剂反应的可逆性也通过减慢当Fe(II)含量降低时还原的指示剂重新氧化而得到证明。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号