首页> 外文期刊>Ultrasound in obstetrics & gynecology: the official journal of the International Society of Ultrasound in Obstetrics and Gynecology >Color Doppler twinkling artifact in fetuses with echogenic intracardiac foci: echocardiographic observation and clinical significance.
【24h】

Color Doppler twinkling artifact in fetuses with echogenic intracardiac foci: echocardiographic observation and clinical significance.

机译:具有回声源性心内灶的胎儿中的彩色多普勒闪烁伪像:超声心动图观察及其临床意义。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: To evaluate echocardiographic characteristics and clinical relevance of color Doppler twinkling artifacts in fetuses with isolated echogenic intracardiac foci (EIF). METHODS: This study included 50 fetuses with EIF, at 18-38 weeks of gestation. Echocardiographic examination, which was performed using a 1.0-5.0-MHz phased array probe, included gray-scale, color and spectral Doppler imaging. Twinkling artifacts were assessed using fetal color Doppler echocardiography on isolated EIF situated in the left and/or right ventricles. The prevalence, appearance and clinical relevance of the color Doppler twinkling artifacts were analyzed. RESULTS: Eight of 50 fetuses with EIF (16%) showed color Doppler twinkling artifacts, which appeared as a rapidly changing color complex seen persistently behind the EIF. The spectra obtained in all eight with color Doppler artifacts were composed of straight vertical bands occurring in mid to late systole and early diastole. After birth, none of 50 fetuses with EIF had structural heart diseases or showed clinical signs of cardiac failure. CONCLUSIONS: Color Doppler twinkling artifacts from isolated EIF occur in some fetuses and may be considered as an additional echocardiographic feature of EIF. Attention should be paid to the identification and interpretation of these artifacts so that they may be accurately distinguished from true color flow generated by atrioventricular valvular regurgitation jets.
机译:目的:评估具有回声源性心脏内病灶(EIF)的胎儿的彩色多普勒闪烁伪影的超声心动图特征及其临床意义。方法:本研究包括50名胎儿,在妊娠18-38周时患有EIF。使用1.0-5.0-MHz相控阵探头进行的超声心动图检查包括灰度,彩色和频谱多普勒成像。使用胎儿彩色多普勒超声心动图仪对位于左心室和/或右心室中的孤立EIF评估闪烁的伪影。分析了彩色多普勒闪烁伪影的患病率,外观和临床意义。结果:50名EIF胎儿中有8名(16%)表现出彩色多普勒闪烁伪像,表现为快速变化的颜色复合体,持续出现在EIF后面。在所有八个彩色多普勒伪像中获得的光谱均由收缩期中晚期和舒张早期出现的垂直垂直带组成。出生后,有EIF的50名胎儿中无一患有结构性心脏病或表现出心力衰竭的临床体征。结论:分离出的EIF引起的彩色多普勒闪烁伪像出现在某些胎儿中,可能被认为是EIF的附加超声心动图特征。应注意这些伪影的识别和解释,以便可以将它们与房室瓣膜反流喷射所产生的真实色彩流准确地区分开。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号