Measuring degradation rates of PV systems without irradiance data

机译:在没有辐照度数据的情况下测量光伏系统的退化率

获取原文
获取原文并翻译 | 示例
           

摘要

A method to report photovoltaic (PV) system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is estimated using a Bayesian statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.