Tests have been performed on animal models shortly post-mortem and on a healthy human subject in order to obtain estimates of the forces which act on suprapubic urinary catheters and similar devices and to develop an abdominal wall simulator. Such data and test methods are required for the systematic design of suprapubic devices because of the dual need to maintain the functionality of devices and to avoid excessive pressure on soft body tissue which could lead to ischaemia and in turn necrosis. In the post-mortem animal models, electrical excitation was applied to the abdominal wall in order to stimulate muscle activity. Two types of transducers were used: a soft membrane transducer (SMT) for pressure measurement and novel instrumented 'tongs' to determine indentation stiffness characteristics in the suprapubic track or artificial pathway created for a device. The SMT has been extensively used in the urethras and bladders of human subjects while the tongs were built specifically for these tests. Only the well-established SMT was used with the human subject; a peak pressure of 22 kPa was obtained. In the animal models the pressure profile given by the SMT had a peak whose position corresponded well with the estimated location of the rectus muscle measured on the fixed tissue section. The peak value was 5.5 kPa, comparable with values likely to cause necrosis if maintained for more than 1 day. Remarkably consistent indentation stiffness values were obtained with the instrumented tongs; all values were close to 0.45 N/mm (33 kPa/mm).
机译:为了获得对作用在耻骨上导尿管和类似装置上的作用力的估计,并开发出腹壁模拟器,已经对死后不久的动物模型和健康人进行了测试。耻骨上装置的系统设计需要这样的数据和测试方法,因为双重需要保持装置的功能并避免对软组织的过大压力,这可能导致局部缺血并进而导致坏死。在验尸动物模型中,将电激励施加到腹壁以刺激肌肉活动。使用了两种类型的换能器:用于压力测量的软膜换能器(SMT)和用于确定耻骨上轨道或为设备创建的人工通路中压痕刚度特性的新型仪器化“钳”。 SMT已广泛用于人类受试者的尿道和膀胱,而钳子是专门为这些测试而建造的。仅将完善的SMT与人类对象一起使用;获得的峰值压力为22 kPa。在动物模型中,SMT给出的压力曲线具有一个峰值,该峰值的位置与在固定组织切片上测得的直肌的估计位置非常吻合。峰值为5.5 kPa,与保持超过1天可能会引起坏死的值相当。用钳子获得的压痕刚度值非常一致。所有值均接近0.45 N / mm(33 kPa / mm)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号