Letter to editor-colony morphology is insufficient to identify methicillin-resistant Staphylococcus aureus isolated from stethoscopes.

机译:写给编辑的形态信息不足以鉴定从听诊器中分离出的耐甲氧西林的金黄色葡萄球菌。

获取原文
获取原文并翻译 | 示例
       

摘要

Dr. Merlin and colleagues examined the prevalence of methicillin-resistant Staphylo-coccus aureus (MRSA) contamination of stethoscopes. They found that 16 (32%) of 50 stethoscopes sampled were MRSA-positive, which was higher than previously reported.1 In this study, stethoscopes were swabbed and samples were inoculated onto mannitol salt agar (MSA) containing 4mug/mL oxacillin. Samples were considered to be MRSA-positive if at least one suspicious colony was found after 72 hours of incubation. However, biochemical tests (Gram stain, coagulase and catalase test as a minimum database) to positively identify these bacteria were not done, calling these findings into question.
机译:Merlin博士及其同事检查了耐甲氧西林金黄色葡萄球菌(MRSA)听诊器的感染率。他们发现,在采样的50个听诊器中,有16个(占32%)的MRSA阳性,高于以前的报道。1在这项研究中,用听诊器擦拭并将样品接种到含4mug / mL奥沙西林的甘露醇盐琼脂(MSA)上。如果在孵育72小时后发现至少一个可疑菌落,则认为样品为MRSA阳性。但是,没有进行能正确识别这些细菌的生化测试(以革兰氏染色,凝血酶和过氧化氢酶测试作为最低限度的数据库),这些发现令人质疑。