Filtration through 0.45μm membrane filters is therninternationally accepted standard for analysis ofrndissolved parameters. However, standard methods dornnot generally provide further guidance on preparationrnof samples for analysis. This study measured colour, UVrnabsorbance at 254nm (UV254) and dissolved organicrncarbon (DOC) on a range of water sources followingrnfiltration with both vacuum and syringe filtration usingrn0.45μm and 0.22μm mixed cellulose esters (MCE) andrnpolyethersulphone (PES) membranes.rnThe filtration step was shown to affect the resultingrnwater quality results due to a range of causes includingrnfouling of the membrane, ineffective removal ofrnturbidity, leaching of organics and/or “over-pressuring”rn(during syringe filtration). Review of this data hasrnshown that effective filtration is critical when preparingrnsamples for analysis to ensure accurate and consistentrnresults. Therefore, it is recommended that filtration forrnpreparation of samples to be analysed for true colour,rnfiltered UV254 and DOC be undertaken with 0.45μmrnPES membranes using vacuum filtration.
机译:通过0.45μm的膜过滤器过滤是分析溶解参数的国际公认标准。但是,标准方法通常不会为制备样品进行分析提供进一步的指导。这项研究在使用0.45μm和0.22μm混合纤维素酯(MCE)和聚醚砜(PES)膜通过真空和注射器过滤进行过滤后,测量了一系列水的颜色,在254nm处的UV吸光度(UV254)和溶解的有机碳(DOC)。结果表明,由于一系列原因,包括膜的结垢,浊度的去除效果不佳,有机物的浸出和/或“过压”(注射器过滤过程中),该步骤会影响最终的水质结果。审查这些数据表明,在准备分析样品以确保准确和一致的结果时,有效过滤至关重要。因此,建议对要分析的样品进行过滤以制备真实颜色的样品,并使用真空过滤用0.45μmPES膜进行UV254和DOC的过滤。