Nowadays, the implementation of pressure management in District Metered Areas (DMAs) is considered one of the most effective tools for leakage control, particularly in large networks and in systems with deteriorated infrastructures and with high pressure. The goal of the methodology proposed in this paper is to identify the optimal entry points at DMAs, determine the network needs in terms of reinforcement/replacement, and fix both the location and settings of different types of Pressure Reduction Valves (PRVs) for leakage control. This methodology is based on an optimisation model, which is solved by a Simulated Annealing algorithm, and the solutions obtained always fulfil the minimum pressure requirements for the network. The objective function comprises the total cost of the DMAs implementation and the economic benefits that can be achieved by pressure management. Finally, the results for two case studies are presented and discussed.
机译:如今,在区域计量区(DMA)中实施压力管理已被认为是控制泄漏的最有效工具之一,尤其是在大型网络以及基础设施退化和高压的系统中。本文提出的方法的目标是确定DMA的最佳入口点,确定加固/更换所需的网络,并确定用于泄漏控制的不同类型的减压阀(PRV)的位置和设置。该方法基于优化模型,该模型通过模拟退火算法进行求解,并且所获得的解决方案始终满足网络的最低​​压力要求。目标功能包括DMA实施的总成本以及可以通过压力管理实现的经济效益。最后,介绍并讨论了两个案例研究的结果。