首页> 外文期刊>Transportation Electrification, IEEE Transactions on >Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform
【24h】

Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform

机译:基于小波变换的电动汽车永磁同步电动机早期间歇性匝间故障检测与定位

获取原文
获取原文并翻译 | 示例
       

摘要

In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.
机译:为了提高混合动力和电动汽车的功能安全性并避免突发故障,开发可靠而强大的车载诊断程序(OBD)非常重要。本文讨论了用于混合动力和电动汽车的永磁同步电动机的定子早期故障诊断和监控。初始定子故障表现为间歇性匝间故障。对这种现象的研究表明,它会在定子电流以及参考电压中产生特定的畸变。故障监视方法基于对这些特定失真的识别以及包含缺陷匝的相位的定位。理论和实验结果表明了该方法的有效性。