首页> 外文期刊>Thin-Walled Structures >Flexural strength of cold-formed steel built-up box sections
【24h】

Flexural strength of cold-formed steel built-up box sections

机译:冷弯型钢组合箱截面的抗弯强度

获取原文
获取原文并翻译 | 示例
       

摘要

Presented in this paper is a study involving finite element analysis to investigate the flexural strength of built-up box sections which have been extensively used in residential and commercial construction in North America. In the North American Specification for the Design of Cold-Formed Steel Structural Members [CSA, North American specification for the design of cold-formed steel structural members, S136, Canadian Standard Association, 2002), there is no guideline or design equation to calculate the flexural strength of this type of section. Both the Lightweight Steel Framing Design Manual [CSA, Supplement 2004 to the North American specification for the design of cold-formed steel structural members, S136, Canadian Standard Association, 2004] and Cold-Formed Steel Framing Design Guide [AISI, Cold-formed steel framing design guide", American Iron and Steel Institute, 1st ed., 2002, 2nd ed., 2007] have recommended that the flexural strength and moment of inertia of the built-up sections to be taken as the sum of the two components based on deflection compatibility of the components. However, this design approximation has yet to be justified by experimental or numerical study especially for the cases of eccentric and concentric loading. In this study, the proposed finite element model of the built-up box sections was validated with the experimental tests carried out by Beshara and Lawson [Beshara B, Lawson TJ. Built-up girder screw connection variation flexural tests, Internal Report, Dietrich Design Group, 2002]. The flexural strengths obtained from the finite element analysis were then compared with the nominal strength evaluated based on the current design method in order to assess its suitability. Parametric studies were carried out for more than 30 specimens to identify factors affecting the flexural strength of cold-formed steel built-up box sections. A recommendation is made for current design practice of evaluating the flexural strength of the box section when subjected to eccentric loading.
机译:本文提出了一项涉及有限元分析的研究,以研究已在北美住宅和商业建筑中广泛使用的组合箱形截面的抗弯强度。在北美冷弯型钢结构构件设计规范[CSA,北美冷弯型钢结构构件设计规范,S136,加拿大标准协会,2002年]中,没有计算准则或设计方程式这种截面的抗弯强度。 《轻型钢框架设计手册》 [CSA,针对冷弯型钢结构构件的设计的北美规范补充2004,S136,加拿大标准协会,2004]和《冷弯钢框架设计指南》 [AISI,冷弯型] 《钢框架设计指南》,美国钢铁协会,第一版,2002年,第二版,2007年]建议将组合截面的抗弯强度和惯性矩作为两个部分的总和基于组件的挠度兼容性,然而,这种设计近似值尚无必要通过实验或数值研究来证明是正确的,尤其是对于偏心和同心荷载的情况。通过Beshara和Lawson进行的实验测试得到了验证[Beshara B,Lawson TJ。大梁螺丝连接变化挠曲测试,内部报告,Dietrich Design Group,2002年。然后,将从有限元分析中获得的所有强度与基于当前设计方法评估的标称强度进行比较,以评估其适用性。对30多个试样进行了参数研究,以找出影响冷弯型钢组合箱截面抗弯强度的因素。对于当前的设计实践,建议对承受偏心载荷时箱形截面的抗弯强度进行评估。

著录项

  • 来源
    《Thin-Walled Structures》 |2009年第7期|807-815|共9页
  • 作者单位

    The Canadian Cold-Formed Steel Research Group, Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, Ontario, Canada;

    The Canadian Cold-Formed Steel Research Group, Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, Ontario, Canada;

    School of Civil Engineering and Mechanics, Langzhou University, Langzhou, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cold-formed steel; built-up box section; flexural strength; moment capacity; eccentric loading; finite element analysis;

    机译:冷弯型钢组合箱部分;抗弯强度;力矩容量偏心载荷有限元分析;
  • 入库时间 2022-08-17 13:10:08

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号