首页> 外文期刊>Thin-Walled Structures >Design resistance of longitudinal gusset-tube K-joints with 1/4 annular plates in transmission towers
【24h】

Design resistance of longitudinal gusset-tube K-joints with 1/4 annular plates in transmission towers

机译:输电塔中带有1/4环形板的纵向角撑板K型接头的设计阻力

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this paper, the design resistance of longitudinal gusset-tube K-joints stiffened with 1/4 annular plates was studied. Full-scale experiments of the K-joints were carried out. The branch loads of the K-joints were equivalent to a vertical shear force (P-v) and a bending moment (M-w). Substantial parametric studies revealed that annular plates had little impact on the ultimate shear force capacity (P-v,P-u). Nevertheless, they could significantly improve the ultimate moment capacity (M-w,M-u) and restrain the chord wall deformation. Moreover, the ultimate moment capacity of K-joints reinforced with annular plates was about 1.3-2.3 times that of K-joints without annular plates. The minimum construction dimensions for annular plates were set to R/d(0) = 0.25 and t(r)/t(0) = 0.75.
机译:本文研究了用1/4环形板加固的纵向角撑板K型接头的设计抗力。进行了K关节的全面实验。 K接头的分支载荷等于垂直剪切力(P-v)和弯矩(M-w)。大量的参数研究表明,环形板对极限剪切力(P-v,P-u)的影响很小。但是,它们可以显着提高极限弯矩能力(M-w,M-u)并抑制弦壁变形。此外,用环形板加固的K型接头的极限弯矩承载力约为不使用环形板的K型接头的极限弯矩承载力的1.3-2.3倍。环形板的最小结构尺寸设为R / d(0)= 0.25,t(r)/ t(0)= 0.75。