首页> 外文期刊>The American Surgeon >Initial Surgical Experience Evaluating Early Tolerance and Toxicities in Patients Undergoing Accelerated Partial Breast Irradiation Using the Contura® Multi Lumen Balloon Breast Brachytherapy Catheter
【24h】

Initial Surgical Experience Evaluating Early Tolerance and Toxicities in Patients Undergoing Accelerated Partial Breast Irradiation Using the Contura® Multi Lumen Balloon Breast Brachytherapy Catheter

机译:初步外科手术经验,评估使用Contura®多腔球囊乳房近距离放射治疗导管对接受局部乳房加速照射的患者的早期耐受性和毒性

获取原文
获取原文并翻译 | 示例
           

摘要

We reviewed our surgical experience with the Contura® Multi Lumen Balloon breast brachytherapy catheter used to deliver accelerated partial breast irradiation and determined short-term treatment efficacy, cosmesis, and toxicity. Forty-six patients undergoing breast conserving therapy, including the use of Contura® catheter, were analyzed. Thirty-four Gray were delivered in 10 fractions. Fourteen patients had stage 0, 24 had stage I, and 8 had stage II breast cancer. Catheters were placed with a closed cavity technique. Median minimum skin spacing was 10 mm (range, 2-18 mm). Median maximum skin doses were 99.7 per cent of the prescription dose. Nine patients were treated with a skin spacing ≤5 mm (2 patients with 2 mm skin spacing). The percentage of patients with excellent/good cosmesis at 6 (n = 26) and 12 (n = 13) months was 100 per cent, respectively. Patient tolerance was assessed on a scale of 0-10 (0 = no pain, 10 = requiring narcotic analgesics). Pain was graded ≤3 in 98 per cent of patients at catheter insertion and 84 per cent at catheter removal. Four breast infections (8.8%) and one symptomatic seroma developed. Adjuvant accelerated partial breast irradiation using the Contura® Multi Lumen Balloon exhibited similar toxicities to standard single lumen, single dwell balloon brachytherapy with improvements in dosimetric capabilities allowing the treatment of patients with skin spacing ≤5 mm. [PUBLICATION ABSTRACT]
机译:我们回顾了使用Contura®多腔气球乳房近距离放射治疗导管的手术经验,该导管用于加速局部乳房照射,并确定了短期治疗效果,美容效果和毒性。分析了46位接受保乳治疗的患者,包括使用Contura®导管。三十四个格雷分十部分交付。 14位患者为0期,24位为I期,8位为II期乳腺癌。用封闭腔技术放置导管。中位数最小皮肤间距为10毫米(范围2-18毫米)。最大皮肤平均剂量为处方剂量的99.7%。 9位患者的皮肤间距≤5 mm(2位患者的皮肤间距为2 mm)。在6个月(n = 26)和12个月(n = 13)时具有出色/良好美容效果的患者的百分比分别为100%。以0-10的等级评估患者的耐受性(0 =无疼痛,10 =需要麻醉镇痛药)。 98%的患者在插入导管时的疼痛等级≤3,而拔出导管时的疼痛等级为84%。发生了四次乳腺感染(8.8%)和一例症状性血清瘤。使用Contura®多腔气球进行辅助乳房局部局部照射的毒性与标准单腔单住球近距离放射疗法相似,并具有剂量学能力的改善,可治疗皮肤间距≤5mm的患者。 [出版物摘要]

著录项

  • 来源
    《The American Surgeon》 |2009年第11期|p.1042-1049|共8页
  • 作者单位

    PHILIP Z. ISRAEL, M.D.,* ANGELA B. ROBBINS, M.D.,* PAULOMI SHROFF, M.D.,* KENNETH HAILE, M.D.,[dagger] D. KEITH POPE, B.S.[dagger]From *The Breast Center, Marietta, Georgia and the [dagger] Department of Radiation Oncology, WellStar Kennestone Hospital, Marietta, GeorgiaAddress correspondence and reprint requests to Philip Z. Israel, M.D., 702 Canton Road, Marietta, Georgia 30060. E-mail: pzisrael@ aol.com.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号