首页> 外文期刊>Terahertz Science and Technology, IEEE Transactions on >500 GHz–750 GHz Rectangular-Waveguide Vector-Network-Analyzer Calibrations
【24h】

500 GHz–750 GHz Rectangular-Waveguide Vector-Network-Analyzer Calibrations

机译:500 GHz–750 GHz矩形波导矢量网络分析仪校准

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We develop an uncertainty analysis that captures the dominant sources of measurement error in state-of-the-art WM-380 (WR 1.5) rectangular-waveguide vector-network-analyzer measurements over the frequency range 500–750 GHz. We use the analysis to assess thru-reflect-line, thru-short-match, and thru-short-radiating-open calibrations. The comparison shows that thru-short-match and thru-short-radiating-open calibrations outperform thru-reflect-line calibrations, and that this is true even when multiple lines and optimal averaging are used to improve the thru-reflect-line calibrations.
机译:我们开发了一种不确定性分析,可以捕获500-750 GHz频率范围内的最新WM-380(WR 1.5)矩形波导矢量网络分析仪测量中的主要测量误差源。我们使用该分析来评估直通反射线,直通短匹配和直通短辐射开放校准。比较结果表明,直通匹配和直通辐射开路校准优于直通反射线校准,即使使用多条线和最佳平均来改善直通反射线校准,也是如此。