摘要

This paper clarifies the following four points on the dynamic behavior of super-high-rise buildings of 700 m high consisting of doubly symmetric frame-tubes with or without braces. A simple and accurate analytical method presented by Takabatake (1996) is shown to be very useful for the preliminary design of such a mega-structure. The building is replaced by an equivalent rod which may allow the main deformation field composed of longitudinal deformation, bending, transverse shear deformation, and shear-lag. It is pointed out originally that, after the horizontal component of earthquake ground motion fades away, noticeable swell breaks out for a long time and that phenomenon is undamping. The serious phenomenon of swell increases remarkably in addition to the action of the horizontal component of an earthquake wave having a long period. The effect of soil-structure interaction on such a structure is discussed using a general analytical method proposed here. An epochal method both to reduce the dynamic response and to leave out the undamping swell after earthquake action is proposed and its effectiveness as a device for vibration control is demonstrated through the numerical computation.
机译:本文阐明了关于700 m高的超高层建筑的动态特性的以下四点,该结构由带有或不带有支撑的双对称框架管组成。 Takabatake(1996)提出的一种简单而准确的分析方法对这种大型结构的初步设计非常有用。用等效杆代替建筑物,该杆可以允许主要变形场包括纵向变形,弯曲,横向剪切变形和剪切滞后。最初指出,在地震地震动的水平分量消失后,明显的涌浪会长时间爆发,并且这种现象不会减弱。除了具有长周期的地震波的水平分量的作用之外,严重的膨胀现象显着增加。使用这里提出的一般分析方法讨论了土-结构相互作用对这种结构的影响。提出了一种既能减小动力响应又能消除地震作用后无阻尼胀大的划时代方法,并通过数值计算证明了其作为振动控制装置的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号