首页> 外文期刊>Solar Energy >A method to calibrate a solar pyranometer for measuring reference diffuse irradiance
【24h】

A method to calibrate a solar pyranometer for measuring reference diffuse irradiance

机译:校准用于测量参考漫射辐照度的太阳总辐射表的方法

获取原文
获取原文并翻译 | 示例
       

摘要

Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component with an estimated uncertainty of +-(3% of reading+1 W/m~2). The method is based on using a modified shade/unshade method, and pyranometers with less than 1 W/m~2 thermal offset errors. We evaluated the consistency of our method by calibrating three pyranometers four times. Calibration results show that the responsivity change is within +-0.52% for the three pyranometers. We also evaluated the effect of calibrating pyranometers unshaded, then using them shaded to measure diffuse irradiance. We calibrated three unshaded pyranometers using the component summation method. Their outdoor measurements of clear sky diffuse irradiance, from sunrise to sundown, showed that the three calibrated pyranometers can be used to measure the diffuse irradiance to within +-1.4 W/m~2 variation from the reference irradiance.
机译:精确的日射强度计校准可追溯到国际公认的标准,对于太阳辐照度测量至关重要。一种校准方法是分量求和,在阳光明媚的天空条件下在户外对总辐射表进行校准,然后将参考全局太阳辐照度计算为两个参考分量的总和,即散射和对向射束太阳辐照度。光束分量通过可追溯至《世界辐射参考》的日光计进行测量,而漫反射分量没有国际公认的参考。在没有这种参考的情况下,我们提出了一种方法,该方法可以一致地校准日射强度计,以测量扩散成分,估计不确定度为+-(读数的3%+ 1 W / m〜2)。该方法基于使用改进的阴影/不阴影方法,并且总辐射表的热偏移误差小于1 W / m〜2。我们通过四次校准三个总辐射表来评估我们方法的一致性。校准结果表明,三个总辐射表的响应度变化在+ -0.52%之内。我们还评估了无阴影校准日射强度计,然后将其着色以测量漫射辐照度的效果。我们使用分量求和法校准了三个无阴影的日射强度计。他们对从日出到日落的晴朗天空漫射辐照度进行室外测量,结果表明,三个校准的日射强度计可用于测量漫射辐照度,使其与参考辐照度的变化在+ -1.4 W / m〜2范围内。

著录项

  • 来源
    《Solar Energy》 |2003年第2期|p.103-112|共10页
  • 作者单位

    National Renewable Energy Laboratory, 1617 Cole Boulevard, Golden, CO 80401, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 太阳能技术;