首页> 外文期刊>SNL Energy Coal Report >NRC report points to design flaws as reason behind San Onofre generator tubal wear
【24h】

NRC report points to design flaws as reason behind San Onofre generator tubal wear

机译:NRC报告指出设计缺陷是San Onofre发电机输卵管磨损的原因

获取原文
获取原文并翻译 | 示例
           

摘要

Faulty computer modeling tied to the San Onofre NuclearnGenerating Station’s steam generator operations is the culpritnbehind the excessive tubal wear that downed the station’s two unitsnearlier this year, according to a Nuclear Regulatory Commissionnreport released July 19 and sent to plant operator Southern CalifornianEdison Co.
机译:根据7月19日发布并发送给工厂运营商Southern CalifornianEdison Co.的核监管委员会报告,与圣奥诺弗雷核电站的蒸汽发生器操作相关的错误计算机建模是导致今年早些时候该电站两个机组的管道过度磨损的罪魁祸首。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号