To realize the on-line and in situ pH detection in soilless culture, a new all-solid-stated pH sensor was presented. The pH sensor consisted of alumina ceramic (Al2O3) substrate, Sb/Sb-2 O-3 working electrode, Ag/AgCl reference electrode, Ag lead and pad. Sb thin film and Ag thin film were obtained by magnetron sputtering method, and then thermal annealing and Nafionmodification was conducted to improve the performance of the sensor. Moreover, the influence of surface area of Sb electrode on the performance of pH sensor was investigated with the area of 4 mm(2), 9 mm(2), 16 mm(2), 25 mm(2) and 36 mm(2), respectively. Through surface morphology analysis, energy spectrum analysis and electrochemical experiments, the pH sensor, which Sb electrode surface area is 16 mm(2), shows excellent comprehensive performance, with high sensitivity (67.3 mV/pH), short response time (less than 3.5 s), good stability (standard deviation less than 2 mV in 700 s period), low hysteresis (less than 1.63 mV) and low drift rate (less than 1.62 mV/h). The developed sensor can be applied in pH detection in soilless culture and is promising to popularize in industrial production.
机译:为了实现在无土培养中的在线和原位pH检测,提出了一种新的全固定的pH传感器。 pH传感器由氧化铝陶瓷(Al 2 O 3)底物,Sb / Sb-2 O-3工作电极,Ag / AgCl参考电极,Ag铅和垫组成。通过磁控溅射法获得Sb薄膜和Ag薄膜,然后进行热退火和NafionModification以提高传感器的性能。此外,研究了Sb电极表面积对pH传感器性能的影响,面积为4mm(2),9mm(2),16mm(2),25mm(2)和36mm(2 ), 分别。通过表面形态分析,能谱分析和电化学实验,SB电极表面积为16mm(2)的pH传感器,具有优异的综合性能,具有高灵敏度(67.3mV / pH),响应时间短(小于3.5) s),良好的稳定性(标准差小于700秒内的2mV),低滞后(小于1.63mV)和低漂移率(小于1.62 mV / h)。发达的传感器可以在无土文化中的pH检测中应用,并且很有希望在工业生产中普及。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号