首页> 外文期刊>Sensors and Actuators >Simultaneous determination of insulin and glucose in human serum based on dual emissive fluorescent nano-aptasensor of carbon dots and CdTe/CdS/ ZnS quantum dots
【24h】

Simultaneous determination of insulin and glucose in human serum based on dual emissive fluorescent nano-aptasensor of carbon dots and CdTe/CdS/ ZnS quantum dots

机译:基于双发射荧光纳米Aptasensor的碳点和CDTE / CDS / ZnS量子点的双发射荧光纳米血清同时测定人血清中的胰岛素和葡萄糖

获取原文
获取原文并翻译 | 示例
           

摘要

A dual emissive fluorescent nano aptasensor was designed for simultaneous detection of human serum glucose and insulin levels. CdTe/CdS/ZnS quantum dots and carbon dots were synthesized and conjugated with the aptamers of glucose and insulin, respectively. The fluorescence of these conjugates was quenched by nano-graphite based on the static quenching and inner filter effect, and restored on the addition of the analytes. All reaction parameters were optimized using analysis of variance, and a polynomial regression model was constructed and verified to explain the effects of reaction parameters on the outcome. The linear ranges of insulin and glucose were 0.2-2 nM and 0.5-7 mM, respectively. The limits of detection for insulin and glucose were 0.018 nM and 0.058 mM, respectively. All the values of relative error % were within the range of - 5.00-4.00%, and the values of relative standard deviation % were = 3.77%. The changes in fluorescence intensity restoration of the probe in the presence of various interfering species were less than 5%, and all the recoveries for glucose and insulin were in the range of 90-110%. The probe was validated and applied successfully to the determination of the stated analytes in human serum. The fabricated aptasensor can be used to diagnose diabetes and its type with a single assay in clinical diagnostic labs.
机译:双发射荧光纳米Aptasensor设计用于同时检测人血清葡萄糖和胰岛素水平。合成CDTE / CDS / ZNS量子点和碳点,分别与葡萄糖和胰岛素的适体共轭。基于静态猝灭和内部过滤器效果,通过纳米石墨淬灭这些缀合物的荧光,并恢复添加分析物。使用方差分析优化所有反应参数,构建多项式回归模型并验证以解释反应参数对结果的影响。胰岛素和葡萄糖的线性范围分别为0.2-2nm和0.5-7mm。胰岛素和葡萄糖的检测限分别为0.018nm和0.058mm。相对误差%的所有值在5.00-4.00%的范围内,相对标准偏差%的值为<= 3.77%。各种干涉物种存在下探针的荧光强度恢复的变化小于5%,葡萄糖和胰岛素的所有回收率在90-110%的范围内。验证探针并成功地应用于确定人血清中所述分析物的测定。制造的aptasensor可用于诊断糖尿病及其型临床诊断实验室中的单一测定。

著录项

  • 来源
    《Sensors and Actuators》 |2019年第8期|321-330|共10页
  • 作者单位

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Univ Sch Chem & Chem Engn State Key Lab Analyt Chem Life Sci Nanjing 210023 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

    Nanjing Med Univ Sch Pharm Nanjing 211166 Jiangsu Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Quantum dots; Carbon dots; Aptasensor; Glucose; Insulin; Diabetes;