首页> 外文期刊>Sensors and Actuators >Simultaneous determination of insulin and glucose in human serum based on dual emissive fluorescent nano-aptasensor of carbon dots and CdTe/CdS/ ZnS quantum dots
【24h】

Simultaneous determination of insulin and glucose in human serum based on dual emissive fluorescent nano-aptasensor of carbon dots and CdTe/CdS/ ZnS quantum dots

机译:基于碳点和CdTe / CdS / ZnS量子点的双发射荧光纳米适体传感器同时测定人血清中的胰岛素和葡萄糖

获取原文
获取原文并翻译 | 示例

摘要

A dual emissive fluorescent nano aptasensor was designed for simultaneous detection of human serum glucose and insulin levels. CdTe/CdS/ZnS quantum dots and carbon dots were synthesized and conjugated with the aptamers of glucose and insulin, respectively. The fluorescence of these conjugates was quenched by nano-graphite based on the static quenching and inner filter effect, and restored on the addition of the analytes. All reaction parameters were optimized using analysis of variance, and a polynomial regression model was constructed and verified to explain the effects of reaction parameters on the outcome. The linear ranges of insulin and glucose were 0.2-2 nM and 0.5-7 mM, respectively. The limits of detection for insulin and glucose were 0.018 nM and 0.058 mM, respectively. All the values of relative error % were within the range of - 5.00-4.00%, and the values of relative standard deviation % were = 3.77%. The changes in fluorescence intensity restoration of the probe in the presence of various interfering species were less than 5%, and all the recoveries for glucose and insulin were in the range of 90-110%. The probe was validated and applied successfully to the determination of the stated analytes in human serum. The fabricated aptasensor can be used to diagnose diabetes and its type with a single assay in clinical diagnostic labs.
机译:设计了一种双发射荧光纳米适体传感器,用于同时检测人的血清葡萄糖和胰岛素水平。合成了CdTe / CdS / ZnS量子点和碳点,并分别与葡萄糖和胰岛素的适体共轭。这些共轭物的荧光基于静态猝灭和内部过滤作用而被纳米石墨猝灭,并在添加分析物后得以恢复。使用方差分析优化所有反应参数,并构建和验证多项式回归模型以解释反应参数对结果的影响。胰岛素和葡萄糖的线性范围分别为0.2-2 nM和0.5-7 mM。胰岛素和葡萄糖的检出限分别为0.018 nM和0.058 mM。所有相对误差%的值都在-5.00-4.00%的范围内,并且相对标准偏差%的值≤3.77%。在存在各种干扰物质的情况下,探针的荧光强度恢复的变化小于5%,葡萄糖和胰岛素的所有恢复率均在90-110%的范围内。该探针经过验证,并成功应用于人血清中所述分析物的测定。所制造的适体传感器可在临床诊断实验室中通过一次测定用于诊断糖尿病及其类型。

著录项

  • 来源
    《Sensors and Actuators 》 |2019年第8期| 321-330| 共10页
  • 作者单位

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210023, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

    Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Quantum dots; Carbon dots; Aptasensor; Glucose; Insulin; Diabetes;