首页> 外文期刊>The Science of the Total Environment >Effect of ventilation strategies and air purifiers on the children's exposure to airborne particles and gaseous pollutants in school gyms
【24h】

Effect of ventilation strategies and air purifiers on the children's exposure to airborne particles and gaseous pollutants in school gyms

机译:通风策略和空气净化器对学校健身房中儿童风险颗粒和气态污染物的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Indoor school gyms are environments characterized by high concentrations of different airborne particulate and gaseous pollutants. In particular, like other naturally-ventilated school environments, in addition to indoor pollutants children can be exposed to sub-micron particles and gaseous pollutants emitted by outdoor sources and penetrating the building envelope; moreover, high concentrations of super-micron particles can be reached due to the resuspension phenomena related to the physical activity performed therein. The present paper aims to evaluate the effect of different ventilation methods (natural ventilation, manual airing) and the use of air purifiers in reducing the indoor concentrations of different airborne particles and gaseous pollutants in school gyms. To this end, an experimental campaign was performed in two naturally-ventilated school gyms in Barcelona (Spain) of different volumes and different distance to major urban roads. Indoor and outdoor measurements of particle number, black carbon and PM_(1-10) concentrations were performed as well as indoor measurements of CO_2 and NO_2 concentrations. The study revealed that the use of air purifiers with windows kept closed (natural ventilation) can lead to a significant reduction in terms of indoor-to-outdoor concentration ratios. In the smaller gym (air changes per hour of the purifiers, ACH, equal to 9.2 h~(-1)) the I/O ratios were reduced by 93% and 95% in terms of particle number and PM_(1-10). respectively; whereas in the larger school gym (ACH = 1.7 h~(-1)) the corresponding reductions were 70% and 84%. For manual airing scenarios, the effect of the air purifiers on outdoor-generated sub-micron particles is reduced; in particular for low ACH values (i.e. ACH = 1.7 h~(-1)), the reduction is quite negligible (6%).
机译:室内学校健身房是具有高浓度不同空中颗粒和气态污染物的环境。特别地,与其他自然通风的学校环境一样,除室内污染物外,儿童可以暴露于由室外来源发出的亚微米颗粒和气态污染物;穿透建筑物包络;此外,由于与其中所示的物理活性相关的重悬浮现象,可以达到高浓度的超微微米颗粒。本文旨在评估不同通风方法(自然通风,手动播出)的效果,以及空气净化器在学校健身房中降低不同空气颗粒和气态污染物的室内浓度。为此,在巴塞罗那(西班牙)的两个天然通风的学校健身房(西班牙)的不同卷和与主要城市道路不同的距离进行了实验活动。进行粒子数,黑碳和PM_(1-10)浓度的室内和室外测量以及CO_2和NO_2浓度的室内测量。该研究表明,使用带窗户的空气净化器保持关闭(自然通风)可以导致室内到室内到室内浓度比的显着降低。在较小的健身房(每小时净化器的空气变化,ACH,等于9.2h〜(-1))I / O比率在粒子数和PM_(1-10)方面减少了93%和95% 。分别;虽然在较大的学校健身房(ACH = 1.7 H〜(-1)),相应的减少为70%和84%。对于手动播出场景,空气净化器对室外生成的亚微米颗粒的影响降低;特别是对于低ACH值(即ACH = 1.7 H〜(-1)),减少是可以忽略不计的(6%)。

著录项

  • 来源
    《The Science of the Total Environment》 |2020年第10期|135673.1-135673.10|共10页
  • 作者单位

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain Department of Civil and Mechanical Engineering University of Cassino and Southern Lazio Cassino FR Italy;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain International Laboratory for Air Quality and Health Queensland University of Technology Brisbane Australia;

    Department of Civil and Mechanical Engineering University of Cassino and Southern Lazio Cassino FR Italy;

    Department of Civil and Mechanical Engineering University of Cassino and Southern Lazio Cassino FR Italy International Laboratory for Air Quality and Health Queensland University of Technology Brisbane Australia;

    Institute of Environmental Assessment and Water Research (IDÆA) Spanish National Research Council (CSIC) Barcelona Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    School gym; Air purifier; Particle number concentration; Black carbon; PM; Indoor air quality;

    机译:学校健身房;空气净化器;粒子数浓度;黑碳;下午;室内空气质量;
  • 入库时间 2022-08-18 22:36:12

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号